Safety information

Roxtec recommends that all installations
are performed without facility operation.
Follow national regulations and installation
codes. Any action affecting the routed
service should be performed according to
manufacturer recommendations.
Components
Roxtec RM PE module
Roxtec RM PE modules
measures in millimeters (mm)
Module size
For cable outer diameter
RM 15 PE
RM 15w40 PE
RM 20 PE
RM 20w40 PE
RM 30 PE
RM 30H90 PE
RM 40 10-32 PE
RM 40 PE
RM 40H80 PE
RM 60 24-54 PE
RM 60 PE
RM 80 PE
RM 90 PE
RM 120 PE
Note:
The range of the modules indicates the smallest diameter of the exposed cable shield to the largest diameter of the cable
jacket. Modules with core can be used as spare parts.
Roxtec RM PE solid module
min-max
3-11
3.5-10.5
4-14.5
3.5-16.5
10-25
10-25
9.5-32.5
21.5-34.5
21.5-34.5
24-54
28-54
48-71
48-71
67.5-99
Installation instructions
Roxtec RM PE systems
Roxtec RM PE solid modules
Module size
RM 10/0 PE
RM 15/0 PE
RM 20/0 PE
RM 30/0 PE
RM 40/0 PE
RM 60/0 PE
RM 30H90/0 PE
RM 40H80/0 PE
RM 10w120/0 PE
RM 5w120/0 PE

Advertisement

loading
Need help?

Need help?

Do you have a question about the RM PE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Roxtec RM PE Series

  • Page 1: Safety Information

    Safety information Roxtec recommends that all installations are performed without facility operation. Follow national regulations and installation codes. Any action affecting the routed service should be performed according to manufacturer recommendations. Installation instructions Roxtec RM PE systems Components Roxtec RM PE module...
  • Page 2 Roxtec RM PE module A: Environmental side A: Environmental side B: Conductive tape B: Conductive tape C: Cable jacket C: Cable jacket D: Cable shield D: Cable shield E: Plastic film F: Removable layers Tools 13 mm spanner Cable jacket removal guide...
  • Page 3: Installation

    Installation The frame must be clean and conduc- The frame must have electrical contact Hold the cable in its final position and Remove the outer jacket. The cable tive. with the potential equalization bar. mark where the cable jacket is to be shield shall be clean and conductive.
  • Page 4 Adapt the layers that shall be in contact Adapt the layers that shall be in contact Fold the conductive tape tightly inside Separate the plastic film from the con- with the cable jacket. the module half from one side. ductive tape and fold it to the side. with the cable shield.
  • Page 5 Place the upper stayplate on top of the Use a Roxtec pre-compression tool to Turn the screws of the wedge counter Lubricate both short sides of the modules. make space for the compression unit if clock-wise to full stop before inserting wedge.
  • Page 6 Insert the wedge so the stop flange (A) Tighten the screws alternately until full 25 mm (A) of the screws shall be Attach the wedge clip to the wedge is in contact with the frame (B). mechanical stop. Max 20 Nm. exposed.
  • Page 7 Disassembly and reinstallation Remove the wedge clip from the Loosen the screws alternately to full Insert a flat tool (A) between the Remove modules and stayplates. wedge. stop. Do not exceed 20 Nm. wedge (B) and the stayplate (C) to remove the wedge.
  • Page 8 Roxtec (“authorized manufacturer”). Roxtec gives no performance by the use of the Roxtec system in a manner or for an application other than for which the guarantee with respect to the Roxtec system, unless (I) all components installed as part of Roxtec system was designed or intended.

This manual is also suitable for:

Rm 15 peRm 15w40 peRm 20 peRm 20w40 peRm 30h90 peRm 30 pe ... Show all