SYSTEM INSTALLATION

It is the responsibility of the plumber/installer that all installations are made in accordance with the
building, electrical, and plumbing codes applicable in the installation region.
GENERAL REQUIREMENTS
Codes and Regulations
Besides these instructions, all installations of the Rheem Crossflow system shall be carried out in accordance
with:
Local Regulations
Municipal Building Codes
Occupational Health, Safety & Welfare Regulations
All plumbing work must be carried out by a qualified person and in accordance with the National
Plumbing Standard AS/NZS 3500.4 and local authority requirements.
All electrical work must be carried out by a qualified person and in accordance with AS/NZS 3000, as
applicable under local regulations, and all local codes and regulatory authority requirements.
In New Zealand the installation must also conform to the New Zealand Building Code.
Permits
All correct permits shall be obtained from the appropriate regulatory authorities.
Safety
Safety is the first priority in all installations. Please observe the safety warnings in this manual and other safety
information provided on the HS Series system. Common safety precautions are:
System must only be installed, commissioned or serviced by a qualified person.
Depending on the model selected, the Crossflow system can be programmed by the installer to supply
hot water at a temperature in excess of 50°C. We recommend that a temperature limiting device be
fitted between the Crossflow system and the hot water outlets in any ablution and public areas such as
bathrooms, ensuites or public amenities, to reduce the risk of scalding. A tempering valve may be
required to comply with local requirements. Refer to the plumbing codes applicable in your area to
determine if a temperature limiting device is required to minimize the risk of scalding.
SYSTEM CONFIGURATION
Refer to the Application Guide for specific system layouts.

CROSSFLOW PRIMARY CONNECTIONS

Position the Crossflow in the required location, as close to the heat source as possible and secure to the
ground if required. Access to the Crossflow and removal of components is from the front, however sufficient
clearance should be left on either side to allow for wrench access.
The Crossflow system is suitable for indoor or outdoor installation. In extreme climatic regions where ambient
temperatures regularly exceed 40
Copyright Rheem Australia PTY LTD 2016
IMPORTANT:
o
C, it is recommended to install the Crossflow system out of direct sunlight.
9
Chapter 3 – Commissioning Procedures
Dec 2016 AQ0901085 Rev C