Do you have a question about the Crossflow RD200 and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Rheem Crossflow RD200
Page 1
Owner’s Guide Installation Instructions Rheem Crossflow ™ Instantaneous Heat Exchange Delivery System This water heater must be installed and serviced by a qualified person. Please leave this guide with a responsible officer.
SETTING THE DELIVERY TEMPERATURE ....................15 SETTING THE GLOBE VALVE ........................16 CLEANING THE HEAT EXCHANGER ......................17 TROUBLE SHOOTING ............................ 17 THE RHEEM WARRANTY - GENERAL ......................19 Copyright Rheem Australia PTY LTD 2016 Dec 2016 AQ0901085 Rev C...
Page 3
This water heater may be protected by one or more patents or registered designs. TRADEMARKS ® Registered trademark of Rheem Australia Pty Ltd. Trademark of Rheem Australia Pty Ltd. NOTE: Every care has been taken to ensure accuracy in preparation of this publication.
316L stainless steel manifolds and fittings, the steel frame is fully welded and hot dip galvanised for superior corrosion resistance. The Rheem Crossflow is available in four sizes and two of the same size unit can be connected where further redundancy or greater capacity is required.
Page 5
*The maximum working pressure of each side of the system will be governed by the lowest operating pressure appliance connected to it. The potable water side (secondary side) must be higher than the non-potable side (primary side). Copyright Rheem Australia PTY LTD 2016 Dec 2016 AQ0901085 Rev C...
Page 6
Chapter 3 – Commissioning Procedures Crossflow System Dimensions (Dual head pump model shown) Copyright Rheem Australia PTY LTD 2016 Dec 2016 AQ0901085 Rev C...
Page 7
Table 2 – Crossflow System Output Table 3 – Crossflow System Pressure Drop (Secondary Side) Secondary Side Pressure Drop vs Flow Rate Flow Rate L/s 200kW 400kW 600kW 800kW Copyright Rheem Australia PTY LTD 2016 Dec 2016 AQ0901085 Rev C...
It is the responsibility of the plumber/installer that all installations are made in accordance with the building, electrical, and plumbing codes applicable in the installation region. GENERAL REQUIREMENTS Codes and Regulations Besides these instructions, all installations of the Rheem Crossflow system shall be carried out in accordance with: Local Regulations ...
Page 10
Crossflow and the closest tank, or pipe material other than copper is being used, consult Rheem for appropriate pipe sizing. Connect hot supply from heating source to the fitting marked “Heating Source In” on the Crossflow.
Ensure equal-friction method is used when making the plumbing connections. The potable water flanges may be joined together for up to two Crossflows. Systems greater than this require the potable water to be connected via a common header. Copyright Rheem Australia PTY LTD 2016 Dec 2016 AQ0901085 Rev C...
(Amps) RD200 RD400 220 -240V AC / 50-60Hz RD600 RD800 Wire the power supply to terminals L, N, Earth within the Crossflow system pump controller housing. Crossflow System Wiring Copyright Rheem Australia PTY LTD 2016 Dec 2016 AQ0901085 Rev C...
Where the saturation index exceeds +0.40, the water is very scaling and an expansion control valve* must be fitted on the cold water line after the non-return valve for the Rheem warranty to apply to a Rheem storage tank. The Rheem warranty does not apply to the heat exchanger.
Page 14
In the table a number of important chemical components are listed, however the actual corrosion is a very complex process influenced by many different components in combination. Rheem's warranty will not cover any resultant faults if the water heater is connected at any time to a water supply that exceeds the limits listed in the table.
Home key to return to the home page. Delivery Skid Temperature Settings Model ECO Setting Factory Setting Max Recommended Temp Setting Refer to Grundfos Magna manual supplied with Crossflow for other system options. Copyright Rheem Australia PTY LTD 2016 Dec 2016 AQ0901085 Rev C...
No further adjustments are required to the system. The system is now completely commissioned. Explain operation and hand over to a responsible officer. Copyright Rheem Australia PTY LTD 2016 Dec 2016 AQ0901085 Rev C...
Ensure pressure limiting valve is of sufficient capacity to meet the requirements of the application. Is pipe sizing adequate to suit the application? Check all valves, heat exchangers and pipework for fouling or blockage. Copyright Rheem Australia PTY LTD 2016 Dec 2016 AQ0901085 Rev C...
Page 18
This page is intentionally blank Copyright Rheem Australia PTY LTD 2016 Dec 2016 AQ0901085 Rev C...
(including wind chill factor). If you require a call out and we find that the fault is not covered by the Rheem warranty, you are responsible for our standard call out charge. If you wish to have the relevant component repaired or replaced by Rheem, that service will be at your cost.
Page 20
WHAT IS COVERED BY THE RHEEM WARRANTY FOR THE CROSSFLOW IS DETAILED IN THIS DOCUMENT Rheem will repair or replace a faulty component of your Crossflow Delivery Skid if it fails to operate in accordance with its specifications as follows:...
Need help?
Do you have a question about the Crossflow RD200 and is the answer not in the manual?
Questions and answers