Connect The Cables To The Fiber Cap L; Ground The Fiber Cap L (Optional) - CommScope Era Installation Manual

Fiber low power carrier access point
Hide thumbs Also See for Era:
Table of Contents

Advertisement

C
ONNECT THE
Complete the following procedures in the order in which they are presented. Unless otherwise noted, each
procedure is applicable to a singular Fiber CAP L (not in a cascade), or to a Primary or Secondary CAP L in a
cascade.
"Ground the Fiber CAP L (Optional)" on page 55
"Connect the Passive RF Antenna" on page 59
"Connect the Fiber CAP L to a Classic CAN or TEN" on page 60
"Cascade a Secondary Fiber CAP L (Optional)" on page 61
"Connect an External Ethernet Device (Optional)" on page 62
"Connect to Vdc Power" on page
Do not remove protective caps from any of the connectors until instructed to do so.

Ground the Fiber CAP L (Optional)

Follow the steps below to ground the OPA only if grounding is required in your locality or if the installation
plans require the CAP L be grounded. The different CAP L installation procedures will tell you when to ground
the CAP L.
The CAP L is equipped with an M6 grounding stud located on the back of the unit; however, grounding is
not necessary. CAP Ls are classified as low-voltage devices and do not have internal power supplies.
CommScope recommends checking your local and national electrical codes to determine if grounding is
a requirement.
Do the following to ground a Fiber CAP L.
Obtain a length of #18 AWG (1.00 mm) insulated stranded copper wire for use as a chassis-grounding
1
wire.
Terminate one end of the wire with a ring terminal.
2
Locate the chassis-ground stud at the rear of the enclosure.
3
Remove the Keps nut from the chassis-ground stud.
4
M0201ANC_uc
© June 2019 CommScope, Inc.
C
ABLES TO THE
62.