  • Page 1 User Manual QHY10/QHY12 Color Astronomy Cooled Camera QHY10/QHY12 User Manual V1.0 WWW.QHYCCD.COM...
  • Page 2: Table Of Contents

    4)CAMERA STRUCTURE AND INTERFACE CONNECTION------------------------------6 new camera! Time spent reading this guide will save you frustration 5)CAMERA DRIVERS INSTALLATION AND QUICKLY MASTERING -------------------7 and maximize the enjoyment of your new QHY10/12 CCD Camera. 6) DC201 IINPUT VOLTAGE RANGE--------------------------------------------------------------9 7)SERVICE TEMPERATURE AND HUMIDITY OF CAMERA--------------------------------9...
  • Page 3: Standard Equipment

    STANDARD EQUIPMENT Make sure that the following items are included in your camera package. If anything is missing, contact the retailer from which you purchased the camera. QHY10(or QHY12) DC201 DC Power Camera Supply Center and Tilt 9pin Power Cable...
  • Page 4 4:IR Cut Optic Window Power Supply Adapter 5 : Heat Sink Exhaust Input Voltage Range 100-240V Optional Air Sealed Box with Electrically Heated Silica Gel 6: 9pin Power Socket 7: USB Socket 8: Guiding/Control Port 9: Heat Sink Air Intake WWW.QHYCCD.COM...
  • Page 5 Camera Software Installation Use the 9-pin cable to connect DC201 and Please download the latest QHY10/12 drivers QHY10/12. Please note: the 9-pin cable has at the http://www.qhyccd.com(win 64/32 one end with EMC ring. This end should be version). This version also supports 64/32 bit connected to the DC201 and not the Camera.
  • Page 6: Dc201 Iinput Voltage Range

    Service Temperature and Humidity of Camera The internal space of CCD camera is relatively airtight. If dew forms on the surface of CCD chip, this indicates Service Temperature of QHY10/12 is from -20C/- that there is higher relative humidity in the CCD 4F to +30C/86F.
  • Page 7 QHY10/12 is from -15℃ to - CCD. Then air will flow out from the gap between 20℃. Please adjust cooling temperature according the unscrewed front cover of CCD and the body of to the ambient temperature.
  • Page 8 3. Put effective desiccant in the dry tube and connect continually with CCD for a long term drying. 4. Don’t supply power to the CCD for several days or even weeks if possible. Use a power controller to control 12V input or AC input. WWW.QHYCCD.COM...
  • Page 9: Qhy10/12 Ccd Chip Read Out Mode And Image Calibration

    The slight differences between the two channels CCD creates slightly QHY10/12 CCD chip uses a 2 phase readout mode. different system gain and offsets between the two The first phase is for the R and Gr pixels. The channels.
  • Page 10: About Controlling For Blooming

    This realize the same exposure time for all pixels The mode of Protection of Cooler double frame exposure will need double exposure The double cooler of QHY10/12 can reach to 40-45 time. So when exposure time is longer, QHY10/12 Centi degrees...
  • Page 11: Clean The Surface Of Ccd Chip

    1. Wash your hands with soap. 2. Take a piece of lens paper, and fold it once or twice (do not fold too many times as the lens paper will get very sharp and the edges may scratch the CCD glass surface) WWW.QHYCCD.COM...
  • Page 12: Set On The Gain And Offset

    CCD camera system gain, which match CCD output signal range and scope of the quantitative ADC to get the best dynamic range. Note A: For some QHYCCD products when you Usual Calibration Method: use bin modes of 2x2,3x3,4x4, images may 1.
  • Page 13: Qhy10/12Mechanical Dimensions

    QHY10/12 back focus distance QHY10/12 mechanical dimensions The back focus length of QHY10/12 is 20mm, as shown without the center and angle adjustment ring. If you connect the center and angle adjustment ring- the rear cut-off distance will increase by about 3mm.
  • Page 14 Although QHY10/12 is supported by many 3 party software, we still suggest you strongly to use There is a M42/0.75 thread on the QHY10/12, which the software distributed with the CCD----EZCAP. can connect directly with the telescope. If it needs Especially when you are first using the QHY10/12.
  • Page 15 Screen View column and a 5x zoom focus image. While it’s exposing, the FWHM column will show the width of stars and the intensity of the star point peak. Generally, smaller FWHM and bigger peak intensity indicate the better focus. WWW.QHYCCD.COM...
  • Page 16 EZCAP can control temperature manually or automatically for the QHY10 camera. Choose Temperature Control from the Setup menu. There are three temperature control options in the window. TEC OFF, Manual and Auto Control. TEC OFF will turn the cooler of the camera off immediately.
  • Page 17 Select ASCOM from the menu of the stretching of image. Camera Mode. Click the button of Advanced button .Select types of QHY10 CCD from the window of ASCOM Camera Choose. and then Color Image Taken click the button of Properties to set some usual The Binning modes of QHY10 include 2x2,4x4.
  • Page 18 Choose Generic RGB from the dropdowns box of and install the ASCOM driver of QHY10。 Select Camera. On the window of Preview check if Install AART3.0 and AART4.0 updates. You will the color is right. And then click OK .You can...
  • Page 19: Image Calibration Of Qhy10/12 Ccd

    Image Calibration of QHY10 CCD If the camera of QHY10 is connected successfully, Image calibration means to calibrate the CCD with AART will show the window of temperature control. a BIAS field, a DARK field and a FLAT field. You...
  • Page 20: Capture Bias Image

    1 * 1 to shoot about (10 -50 sheets) BIAS Master image. Save this image. BIAS image. Save and overlay these images to form a Dark Master image. Save the image. WWW.QHYCCD.COM...
  • Page 21: Capture Flat Image

    , which means you have gotten DARK image which be calibrated by BIAS Field (D-B) 20000-30000 pixel of flat-field image. Images of BIAS Master, DARK Master and FLAT Master will be calibration data as image post- processing of the captured images . WWW.QHYCCD.COM...