General Requirements; Related Documents - Lochinvar Mini Copper-Fin MCW91CE Installation, Commissioning And Maintenance Instructions

High efficiency gas fired water heaters and boilers
Table of Contents

Advertisement

4.0

GENERAL REQUIREMENTS

The Lochinvar Mini Copper-Fin has been designed to operate trouble free for many years. These instructions
should be followed closely to obtain the maximum usage and efficiency of the equipment. PLEASE read the
instructions fully before installing or using the appliance.

4.1 RELATED DOCUMENTS

It is law that all gas appliances are installed by competent persons, in accordance with The Gas Safety
(Installation and Use) Regulations 1998. Failure to install appliances correctly could lead to prosecution. It is in
your own interest, and that of safety, to ensure that this law is complied with.
The installation of the equipment MUST be in accordance with the relevant requirements of the Gas Safety
Regulations, Building Regulations, I.E.E. Regulations and the bylaws of the local water undertaking. The
installation should also be in accordance with any relevant requirements of the local gas distributor and local
authority.
In addition the installation should follow the relevant guidance offered in the following documents. It is not
practical to list all relevant information but emphasis is placed on the following documents, as failure to comply
with the guidance given will almost certainly result in an unsatisfactory installation:
BS EN 1858: 2003
BS 5440-1: 2008
BS 5440-2: 2009
BS 6644: 2005
70kW
+ A1: 2008
BS 6700: 1997
BS 6880: 1988
Parts 1, 2 and 3
BS 7074: 1989
Parts 1and 2
BS 7671: 2008
CP 342:
Part 2 1974
IGE/UP/1:
Edition 2
IGE/UP/2:
Edition 2
Chimneys. Components. Concrete flue blocks
Installation and maintenance of flues and ventilation for gas appliances of rated input
not exceeding 70kW net (1st, 2nd and 3rd family gases)
Part 1: Specification for installation and maintenance of flues
Installation and maintenance of flues and ventilation for gas appliances of rated input
not exceeding 70kW net (1st, 2nd and 3rd family gases)
Part 2: Specification for installation and maintenance of ventilation for gas
appliances
Specification for Installation of gas fired hot water boilers of rated inputs between
and 3
(net) and 1.8MW (net) (2
nd
Design, installation, testing and maintenance of services supplying water for
domestic use within buildings and their curtilages
Code of practice for low temperature hot water systems of output greater than 45kW
Application, selection and installation of expansion vessels and ancillary equipment
for sealed systems
Requirements for electrical installations, I.E.E. wiring regulations seventeenth edition
Code of practice for centralised hot water supply-buildings other than dwellings
Installation pipework on industrial and commercial premises
Gas installation pipework, boosters and compressors on industrial and commercial
premises
family gasses)
rd
9