CONDENSER
Measurement of capacity substitutes for checking the condenser. The capacity of the condenser cannot be measured by
using the circuit tester. Therefore. the generator is run with a new condenser to see whether or not the generator performs
normally. If the generator performs normall>-. the condenser is normal.
Reference:
If an instrument
ii available
for measuring
the capacity
of the condenser,
the total capacity
range should
be 70
to 7 7pF fat 20°C).
When the condenser
displays
its total capacity
within
this range, it is normal.
11-6
RECTIFIER
Using the circuit tester. measure the resistance between
each of the two terminals of the rectifier. The rectifier is
considered normal when the respective resistances have the
values specified below.
NOTE:
Each of the given
values changes with the polarity
of the circuit
tester.
Green
Red
White@
[
01
3
:...16RI
.160
1
@
#3
. .
\
Y
,
The polarity
of the circuit
tester
Table 7 l-4
-30-