  • Page 1 Basic quattro No. 2954-0005 / 2954-1005 Ideen für die Dentaltechnik...
  • Page 5: Application Area

    Basic quattro No. 2954-0005 / 2954-1005 ENGLISH 3. Safety Information 1. Introduction We are pleased with your decision to 3.1 Employed Symbols purchase the Basic quattro. The following symbols are used in these Please read the following operat- instructions and on the unit: ing instructions carefully and Danger observe all the information they...
  • Page 6: Liability Exclusion

    • Check the tanks and the lids regu- larly on damages and replace them 3.3 Liability Exclusion in case of doubt. Renfert GmbH shall be absolved from • Check the tank cover for correct all claims for damages or warranty if: seating prior to beginning operation.
  • Page 7: Cleaning & Maintenance

    5. Cold silanization in the mains power supply yet! sandblasting unit 4.2 Starting the Unit The Basic series of Renfert sandblast- 1. Connect the mains power cord to the ing units is exclusively recommended by sandblasting unit (Fig. 11), then plug 3M ESPE for use with ROCATEC™.
  • Page 8: Spare Parts

    6.5 Sandblasting Hose Replacement 8. Warranty 1. Disconnect the sandblasting unit from Provided the unit is properly used, Renfert the compressed air supply (Fig. 5,4,3). warrants all parts of the Basic quattro for 2. Refer to insert no. 21-9162 for the a period of 3 years.
  • Page 9: Shipping Notes

    • Request a Renfert shipping box 1 Foot switch (Tel.: +49 7731 8208-61). 1 Connection set • If a Renfert shipping box is not used, al- 1 Fluorescent tube, with lamp cover ways disassemble any additional tanks 1 Accessories set (otherwise we can assume no liability for shipping damage).
  • Page 10: Troubleshooting Guide

    14. Accessories No. 1583-1005 110 μm [150 mesh], white 5 kg canister Additional tanks No. 1583-1020 110 μm [150 mesh], No. 2954-0050 25-70 μm Right / blue white 20 kg bucket No. 2954-0051 25-70 μm Left / red No. 1587-1005 125 μm [115 mesh], No.
  • Page 11 Problem Possible cause Corrective action Only air, no or very • The dosage nozzle in • Wear protective goggles. little abrasive. the mixing chamber is • Unscrew tank lid. blocked due to conta- • Remove sand. minated or moist sand. •...
  • Page 12 Problem Possible cause Corrective action Only air, no or very • Mixing chamber filter Make certain their is no abrasive little abrasive. combination blocked residue on the threads. Attention: Never operate the unit without filters! Do not reinstall used filter sets! •...

This manual is also suitable for: