Assembly of the evaporation unit

The evaporator is assembled within the coldroom on the
ceiling.
Using the two drawings 2.2.1 and 2.2.2 four holes are drilled
on the ceiling.
Cut edges should be rust proofed.
Anchor evaporation unit with enclosed plastic scres on the
U-profiles on the coldroom ceiling.
2.2.1 Drilling diagram for large evaporation unit
(CS 2000, CS 2800, FS 1400, FS 1800, FS 2400)
Distance to wall 140 mm for wall thickness 150 mm.
Distance to wall 230 mm for wall thickness 60 mm.
2.2.2 Drilling diagram for small evaporation unit
(CS 0900, CS 1300, FS 0900)
Distance to wall 165 mm for wall thickness 150 mm.
Distance to wall 255 mm for wall thickness 60 mm.