ELECTRICL CABLE TO CIRCULATION PUMP

3 - OPERATING CENTRAL HEATING STOVE

3.1 When installation becomes completed, you must open the valve in order to give water to boiler's return
-
line (Figure
2/9) from service water line.
3.2 Valve must be closed when 1/4 of expansion tank is filled.
3.3 Empty cable ends must be connected to circulation pump (Figure
3.4 Plug must be inserted to grounded socket. One of the lamps (from two lamps
that there is electricity and the other one indicated that electricity comes to circulation pump (Figure
2/3). Operating of circulation pump is provided by adjusting the thermostat of pump (Figure
zero degree.
3.5 By removing big yellow screw on the circulation pump, be sure that the tip of motor shaft taking place
inside turns. If it is not turning, shaft must be turned once with the screwdriver. Big yellow screw is
applied
place when shaft
to its
3.6 Air of the cores must be removed. Water level of expansion tank must be controlled.
3.7 Water is given to the system from boiler's inlet pipe (Figure
3.8 After becoming sure that there is no leakage in the system, fuel is loaded to the firing chamber and
then the fire is set. Pump thermostat (Figure
temperature of the
3.9 Temperature of the boiler's water (which is determinant for the temperature of the room) is adjusted
from chain driven thermostatic regulator (Figure
controls burning speed of Central Pleating Stove and it maintains the heat of the water fixed at the
adjusted temperature.
3.10 In order to obtain a good heat, coal must be preferred by having 6.000-7.000 kcal/hour value, having
less ash residue and it must be dry and without dust and must have orange and walnut size. Big
coal comforts air inlet.
CONNECTION DIAGRAM OF
starts to turn.
exceeds 40°C.
water
-
2/3) as seen in (Figure
-
2/9) from
-
3/10) is adjusted. Pump will start working when the
-
2/6). Chain driven thermostatic regulator automatically
Figure -3
Figure -4
-
3)
-
-
Figure
3/10) show
-
2/11) to