2 - CENTRAL HEATING STOVE with FIREPLACE

2.1 Central Heating Stove
surrounding. It can also be installed in a room or in the kitchen having good draft. It is compulsory
to use open expansion boiler.
2.2 Central Heating Stove can not be installed in the bedroom or outside of the house.
2.3 Chimney must be cleaned well before applying stove pipes.
2.4 Attention
be paid so that the pipes of the stove get linked to each other in good order and one
must
within the other.
2.5 Bad quality of the chimney draft affects the output of the stove and at the same time, it can also cause
harmful results for the health.
2.6 Central heating installation must be done by the authorized installer by taking installation's connection
diagram into consideration.
2.7 Draft of the chimney must be well and powerful. This particularity can be tested by approximating the
flame to the chimney and it can also be done with a piece of paper. In this case, piece of paper is
pressed to the opening of the chimney and is the piece of paper remains suspended, it means that
the draft of the chimney is good.
In order
2.8
to prevent the
applied on the exit of the chimney.
2.9 Gas warning detector must be applied in the place where Central Heating Stove takes place.
2.10 Installation must be done by being in compliance with the connection diagram taking place in Figure-2.
2.11 For the circumstances when it is required to dismantle Central Heating Stove, its connection must
be done to the installation with "conic pipe couplings".
2.12 Steam exit taking place on the expansion tank
medium.
2.13 Main line pipes of the installation must be R1" (one finger). Horizontal pipes for the final cores are
selected as R 3/4".
insulation must be done for
2.14 Very good heat
adequate heat can not be obtained from the cores.
2.15 One or two pipe bend(s) 2 meters of pipe is ideal.
2.16 A strong stove tray, capable of carrying the weight and heat resistant for Central Heating Stove, must
be placed under. Distance of Central Heating Stove from the wall must be 40 cm.
2.17 Air supply is automatically done with chain driven thermostatic regulator.
2.18 Chimney of the device can not be used together with another device. Chimney type is independent
and it is not suitable for collective usage.
2.19 Ash taking place in the top cleaning lid (Figure
it must be cleaned with the rake.
2.20 Mounting of Central Heating Stove to its place is as explained below.
2.21 In models having chain driven thermostatic regulator (Figure
with the numeric values taking place on it.
2.22 Elimination of extreme heat: if electricity cut off occurs, by-pass valve (Figure 4/4) must be opened.
In models having chain driven thermostatic regulator, bottom air-inlet duct will be closed and burning
will be decreased.
MOUNTING INSTRUCTIONS: This device must be mounted by being in compliance with entire
domestic (national) legislation and related national and European Standards.
Type of Device
Nominal Heat Power (kw)
Area Heating Power (kw))
Water Heating Power (kw)) :
Mass of the device (kg)
Highest Water Operating Pressure (bar) : 1,2

AND ITS SPARE PARTS

be placed in the house because it also provides convection from its
must
backfire of
the chimney, "chimney cap" which turns with the wind must be
must
the pipes passing
be extended
restroom-bathroom or to ventilation
to
from
the concrete
-
1/11) must be controlled once in a month. If needed,
-
2/6), adjustment of
301
302
401
25
25
25
20
20
20
22
22
150
120
175
1,2
1,2
floor. Otherwise,
the heat is done
303
25
20
22
75
1,2