INSTALLATION INSTRUCTIONS

UNCRATING INSTRUCTIONS

1. Verify that the number of items on the Bill of
Lading matches the number of items received.
2. Check for shipping damage. Take photographs of
any damage.
IMPORTANT
If damage is found, immediately file a claim with the
carrier before proceeding further.
3. Check the items received to make sure they agree
with the ordering information including verification
of data on the unit nameplate.
IMPORTANT
Do not discard any components or accessories.

MOUNTING LOCATION

Verify feasibility of the installation location selected
with respect to accessibility to the heater for service
and maintenance functions. Ensure the positioning of
the heater does not inhibit fork truck operation, stor-
age rack locations, or other operations within the facil-
ity. Ensure the heater inlet and outlet are not blocked
or severely restricted in any way that would affect the
rated airflow through the heater or affect the desired
air distribution pattern of the heater.
S-Series Technical Manual
It is the responsibility of the installer to communicate
any potential problems with the installation to the per-
son or persons responsible for providing the installa-
tion instructions or drawings prior to proceeding with
the installation.
Where the mounting height of the heater is a con-
sideration, work platforms or service lifts should be
provided for accessibility to the equipment for ser-
vice and maintenance activities.
Field constructed intake accessories should be de-
signed to minimize the entry of snow and rain.
The minimum clearance from the face of the elec-
trical control enclosure to surrounding grounded
surfaces for service activities is 42". Adequate clear-
ance of 42" for burner removal is also required.
Access for service functions is also required on the
side of the unit opposite the control enclosure for a
distance of 24".