Download Print this page

HORNE TSV1-3 Installation, Operating, & Maintenance Instructions page 6

Thermostatic shower valve with automatic diverter valve

Advertisement

Fig. 6
9) Test for Leaks in Pipework
Ensure that the TSV1-3 on/off control is closed (i.e. turned fully clockwise) and open the supplies.
Open the low level servicing valves on the TSV1 casing (Fig. 6). Adjust the temperature control and
check for any water leaks upstream of the TSV1-3 valve. Make good any leaks found. The valve is
now ready for commissioning.
Note that if the controls, enclosure and shower accessories require cleaning then care must be taken
not the scratch them in the process. Wash off any surface dust with the shower spray before cleaning
with soapy water.
DO NOT USE ANY ABRASIVE CLEANERS OR SOLVENTS OR THE SURFACES MAY BE DAMAGED.
Issue 4 June 2016
Horne Engineering Ltd
Fig. 7
6

Advertisement