Thermostatic shower valve with automatic diverter valve

Advertisement

Installation Instructions (Surface Mounted with Auto Diverter valve)
General
The surface-mounted panel is supplied with a fitting kit containing the necessary fixings to attach it to the wall,
and with hex keys to assist with routine maintenance.
Installation
Installation of the pre-plumbed panel is particularly simple and involves mounting the panel on the wall,
connecting and flushing the water supplies.
1) Position the Pre-plumbed Panel
Identify a suitable position for the panel and mark a line on the wall level with the top of the casing.
Mark a point on the wall that is on the required centreline for the casing, 15mm below the line of the
top of the casing, for the support screw (see Fig. 1).
2) Install the Support Screw
Drill a 7.0mm dia hole in the wall and insert a wallplug and screw, leaving the head of the screw 11-
13mm from the wall surface. Note that a stainless steel screw (corrosion resistant) is supplied for this.
3) Hang the Panel on the Support Screw
Release the top cover of the panel by removing the four T-15 screws. Hang the panel on the support
screw by the larger hole in the middle of the back strap and let this take the weight of the enclosure
(see Fig 2).
Fig 1
4) Mark out the 4 Support Holes
Ensure that the panel is hanging true and then mark out the holes for the 2 upper support screws.
Remove the bottom cover of the panel and mark out the 2 lower support screws (see Fig 3).