Warranty In accordance with IKA warranty conditions, the warranty period is 24 months. For claims under the warranty please contact your local dealer. You may also send the machine direct to our factory, enclosing the delivery invoice and giving reasons for the claim. You will be liable for freight costs.
- biological and microbiological materials. Risk of burns! DANGER Exercise caution when touching the suitable extractor hood. Please contact IKA if you have any housing parts and the attachments. questions. They may become hot.. Pay attention to the residual heat after switching off.
Commissioning Make sure before start-up of the equipment that the drain hose the device is ready to operate after plugging in the mains plug. leads into a drain! If these procedures are not followed, safe operation cannot be guaranteed and/or the equipment may be damaged. For protection in transport, a strip of foamed material is inserted Observe the ambient conditions (temperature, humidity, etc.) listed between the shaker table and the inner face or the rear wall.
Timer The desired shaking duration is set on the operator panel of the timer using the Time +/- keys. The shift key can be used to switch from hour mode to minute mode. The Time On/Off key activates the timer and shaking functions. When the time is up, the shaking function stops and an acoustic signal is given off.
Set the desired temperature on the KS 3000 and switch the heating function on. The cooler is connected to an external cooling unit (e.g. IKA KV 600) via the plug connection at the back of the appliance. The inlet and outlet connections are labelled accordingly at the back of the appliance.
Error codes An error is indicated by an acoustic signal and an error code is displayed. E. g.: If faults cannot be eliminated directly, you must perform a RESET (see „Resetting parameters to the factory settings“)! If the faults still cannot be eliminated, the appliance must be inspected by a technical service. Error Description Cause Effect...
- Install the driver automatically, if it is not already installed to the laboratory instrument (slave). - Prompt the user to perform a manual installation - In this case, select the appropriate download from the IKA processor. Even error codes cannot be spontaneously communi- Internet product page.
Page 10
Overview of the NAMUR-instructions <0: error code: (-1) - 1: error 1 Abbreviations: - ... (see table) X,y = numbering parameter (integer number) -31: error 31 variable value, integer -83: wrong parity value of variable, floating point number -84: unknown instruction X = 1 Pt1000 medium temperature (external temperature sensor) -85: wrong instruction sequence X = 2 temperature (incubations room)
Maintenance and cleaning The shaker KS 3000 i control and KS 3000 ic control is mainten ace free. It is subject only to the natural wear and tear of compo- Cleaning of the collec- nents and their statistical failure rate.
Accessories AS 260.1 AS 260.3 Bowl attachment AS 260.5 Separating funnel attachment AS 260.2 STICKMAX PC1.1 Adapter Technical data Design voltage 230 ± 10% 115 ± 10% Design frequency 50/60 Heating power 1000 Input power 1120 Speed range 10 - 500 Heating temperature range °C RT +5 ..