Removing The Radio% Cover
Remove
the cover
by inserting
a
+0:
+
000
screwdriver into the 4 removal points
at the bottom of the unit and gently
o r
releasing the locking tabs from the
cover slots as shown.
Setting The Jumper Options (Set Before Installing)
(J2)
Zone
Inputs
Activate
on High
or
Low
(JI ) Fault
Output
Select
(J3)
ECP/7720P
(J4)
Trigger
Voltage
outputs
Refer to the diagram below when setting jumpers.
If using zone input connections, set the J2 jumper so that zone 1 & 2 inputs are
activated either with a ground or with a positive voltage, whichever is required.
If the trigger level is set for positive voltage, +4.5 to +14.2 volts must be applied to
zones 1 & 2 to trigger an alarm. If the zone is connected to a normally high voitage
trigger (i.e. goes iow on alarm), invert this zone when programming (programming
questions 12 & 13).
if ground is selected, zones 1 & 2 are internality puiied up to 5 voits through a 10k ohm
resistor. This voitage shouid normaiiy be puiied down (ciosed contact to ground) and
released for aiarrn (opening the contact). If
a
normaiiy open contact is being used, invert
this zone when programming (programming questions 12 & 13).
The radio fauit output reiay may be programmed for either FAIL-SAFE mode (reiay
aiways energized) or LOW CURRENT mode (reiay normaily de-energized) by seiecting
Yes or No to programming question 26: FLT REL ON (Y/N). In addition, the reiay can be
set for either N.O. or N.C. operation (in either fail-safe or low current modes) using the
J1 jumper.
When faii-safe mode is seiected, the relay wili change states (and trigger a dialer, if
connected) in the event of power ioss. Note that fail-safe mode increases the standby
current by about 10mA, which results in lower battery backup time (about 15Yo)in the
event of power ioss. Set the J1 jumper to position A or position B, as foiiows:
Prog. Ques. 26
JI Jumper Setting (reiay N.O. or N.C.)
Fault Reiay ON (energized) Pos. B
Pos. A
NO
N.C.
N.O.
YES
N.O.
N.C.
Use the 7720P position when
programming with a 7720P programming
tool. The ECP function is not supported
by the 7720V2.
This output connector provides for two
voitage outputs which are deriied from the
batte~ through 1K resistors which are
suitable for use with zones 3 and 4 when a
dry contact driving device is being used.
Connection to this output maybe made
using the optionai Ademco cable, part
number 7720TVC.
7720TVC
TRIGGER CABLE
RADIO FAULT LED
POWEWMESSAGE
WAITING LED
TRANSMIT LED
J3: CONNECTED TO ECP LINES
COMMON PIN
:ONNECTED TO 7720P PROG. TOOL
J2: ZONE 1 & 2 TRIGGERING
TRIGGER ON GROUND
COMMON PIN
TRIGGER ON 4.5VDC-12VDC
J1 : RADIO FAULT
RADIO FAULT CONTACTS POS
A
COMMON PIN
RADIO FAULT CONTACTS POS
B
J4:
T RIGGER VOLTAGE OUTPUTS
TRIGGER VOLTAGE
COMMON PIN
lRIGGER
VOLTAGE
8'
di-
cl-
Q-
o-
n-
n-
rt--
rl--
cl-
- JUMPER POSITIONS DIAGRAM-
TYPiCAL TRIGGER CABLE CONNECTIONS