Page 3
Equipped with a ceramic lining to the combustion cham- Put your mind at rest ber door of generous thickness, plus an insulating At MHS Boilers we provide a jacket of 80mm depth of foil backed high density glass life time maintenance and ser- wool;...
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS General Specification Monomax boiler units are formed by matching a gas, gas Installation oil or gas/gas oil mix burner, depending on requirements, with a high quality, high performance steel boiler. To obtain Warning: this boiler is designed to heat water to a maximum performance from the unit, the burner is temperature below boiling point at atmospheric pressure;...
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS Control Panels To gain access to the controls, push and release on P and rotate transparency panel towards you. To close the transparency panel, rotate in vertical position and push and release it on P.
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS Fitting the boiler insulation page. 14...
Page 15
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS Fitting the casing Monomax N - NS - NC - NCS (up to 420 model) - Wrap the glass wool around the boiler body leaving the Fig.
Page 16
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS Fitting the casing Monomax N - NS - NC - NCS (from 510 to 1300 models) - Wrap the glass wool around the boiler body leaving the bulb well (P) on the top side exposed.
Page 17
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS Fitting Electrical Panel Monomax N - NS - NC - NCS (from 1400 to 3500 models) The assembly described hereafter concerns the control - Remove the half cut plastic plate K, insert the cable panel installation placed on the left side of the boiler.
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS Fitting the casing Duomax N - NS P1 - Bulb well for 1 st boiler: Regulation boiler thermostat Security thermostat Minimum thermostat (Circulator consent thermostat) Thermometer P2 - Bulb well for 2 nd boiler:...
Page 19
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS Fitting the casing Duomax PN - PNS Fig. 11.2-3 - Wrap the glass wool around the boiler body leaving the bulb well (P) on the top side exposed. - Fixing in the right position the boiler body (65mm between the boilers, see pag.
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS Fitting the Burner In order to fit the burner correctly, follow the below instruc- tions: 1 - tighten the stud bolts provided with the boiler onto the boiler door;...
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS Water treatment Limestone deposits strongly impair the efficiency of heat Clean as follows: exchange between combustion gases and the system water, causing a decrease in the performance of the - switch off the heating unit and disconnect the power appliance (see graph);...
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS Prevention of Condensation Condensation within steel boilers is very harmful and precautions must be taken within the system design to prevent condensation from occurring within the flueways. The boiler should work at a return temperature in excess of 60°C. In order that the boiler should reach this temperature as quickly as possible, it is imperative that an anti-condensation system is installed.
Page 23
Furthermore, in accordance with BS6644, for boiler/s with an input greater than 70kW net, an automatic pressurization unit must be installed to automatically replenish any lost system water. For information on the comprehensive range of pressurization units available from MHS boilers, please visit our website, www.mhsboilers.com...
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS Electrical connections 20.1 ELECTRICAL BLUEPRINT BASE CONTROL PANEL FOR MONOMAX N, NS, NC AND NCS pag. 25 ... . 20.1.1 ELECTRICAL CONNECTION BLUEPRINT TO BASE CONTROL PANNEL FOR MONOMAX BOILER NC AND NCS...
Page 25
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS 20.1 Electrical Blueprint base control panel for Monomax N,NS,NC and NCS 13 14 19 20 STAB 6,3 A max fuse burner switch block bulb recirculation thermostat operation bulb security thermostat...
Page 26
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS 20.1.2 Electrical connection Blueprint to base control panel for Monomax N and NS Boiler with single-phase burner WARNING: THE 4 POLES TERMI- ATTENZIONE: NAL BOARD (W4) IS CONNECTED LA MORSETTIERA A 4 POLI (W4) VA COLLEGATA SOLO SE ALLA CALDAIA ONLY IF THE BOILER IS COUPLED...
Page 27
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS 20.2 Electrical Blueprint base control panel for Duomax N,NS,P and PNS page. 27...
Page 28
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS 20.2.1 Electrical connection Blueprint control panel for Duomax N,NS,P and PNS boiler, base model or with electronic management of hi-low flame, with single-phase burner WARNING: THE 4 POLES TER- W7-a W4-a...
Page 29
MONOMAX N / NS - NC / NCS DUOMAX N / NS - PN / PNS page. 29...
Page 30
MHS reserves the right to make any adjustments, without prior notice, which it considers necessary or useful to its products, without affecting their main features. MHS Boilers Ltd 3 Juniper West, Fenton Way, Southfields Business Park, Basildon, Essex, SS15 6SJ - tel. 01268 546700 - fax 01268 888250...
Need help?
Do you have a question about the MONOMAX N Series and is the answer not in the manual?
Questions and answers