Continuous Drainage
• Pull out the rubber plug from the drain tube.
• Connect the drain hose to the tube and lead the hose to a proper collecting basin. Make sure never to
crimp the drain hose.

7. Troubleshooting

Problem
Unit does not work
Unit stops running
automatically
No cool air when running under
cooling mode
No cool air when running under
dehumidifying mode
Error code E3 displayed
Error code E4 displayed

8. Technical Specifications

Power Supply
Power Consumption
Fuse
Cooling Power
Cooling Capacity
Airflow
Humidity Extraction
Noise
Length of Connection
Dimensions
Indoor Unit
Outdoor Unit
Weight
Indoor Unit
Outdoor Unit
For more info concerning this product, please visit our website www.perel.be
The information in this manual is subject to change without prior notice.
EAC12S
Possible Cause
Power supply fault
• Power plug not connected
• Defective power plug or cord
• Defective fuse
Timer has elapsed or environmental
temperature is cooler than set
temperature
• Timer has elapsed or
environmental temperature is
cooler than set temperature
• Evaporator is covered with frost
Evaporator is covered with frost and
unit is defrosting
Air exhaust pipe is defective
Water storage tank is full
max. 240VAC / 50Hz
max. 1200W
3.15A / 250V
3200W
12 000 BTU/h
350m³/h
1.5l/h
< 52dB (A)
1.8m
870 x 445 x 400mm
535 x 485 x 200mm
42kg
10kg
7
Solution
• Plug in correctly
• Replace power plug or cord
• Replace the fuse
Disable the timer function or start
manually
• Disable the timer function or start
manually
• Unit is defrosting. Unit will restart
after defrosting period
Unit is defrosting. Unit will restart
after defrosting period
Replace the air exhaust pipe
Drain the water storage tank