FRÄNKISCHE profi-air 180 flat Installation And Operating Instructions Manual

Advertisement

Quick Links

profi-air
180 flat connection box
®
Installation and operating instructions
DRAINAGE SYSTEMS
ELECTRICAL SYSTEMS
BUILDING TECHNOLOGY
INDUSTRIAL PRODUCTS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the profi-air 180 flat and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FRÄNKISCHE profi-air 180 flat

  • Page 1 profi-air 180 flat connection box ® Installation and operating instructions DRAINAGE SYSTEMS ELECTRICAL SYSTEMS BUILDING TECHNOLOGY INDUSTRIAL PRODUCTS...
  • Page 2: Table Of Contents

    The decisive role with regard to the data on products and services is always played by the order placed, the product actually purchased and the documentation in connec- tion with it, or the information provided by our specialist staff in each specific individual case. FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 3: General

    Keep these installation and operating instructions near the device during Installation of the profi-air 180 flat the entire life of the profi-air 180 flat connection box must be carried out connection box. according to applicable local con- struction, safety and installation reg- ulations.
  • Page 4: Intended Use

    Additional notices Reference to other sections and/or guidelines of the manufacturer. Disposal instructions 2 Intended use The profi-air 180 flat connection box is tion unit. It is connected directly to the an extension of electric connection mainboard of the ventilation unit.
  • Page 5: Technical Data

    5 Technical data 5.1 Connection options Fire alarm External filter alarm Standby switch External fault alarm Room humidistats External fan activation 5.2 Dimensional drawing 170 mm 100 mm FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 6: Wiring Diagrams

    All connection activities must be carried out by authorised and qualified personnel only. Additionally, applicable local regulations and safety provisions must be observed. FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 7: Modbus (Connection To The Ventilation Unit)

    180 flat ventilation For information on the connection to the mainboard of the profi-air 180 flat ventilation unit, see installation and operating instructions of the ventilation unit. Since the external control unit delivered...
  • Page 8: Humidistat Input

    Status T2AC The digital input on the control board of the ventilation unit can also be used to connect the room humidistats to the profi-air 180 flat ventilation unit. See profi-air 180 flat operating instructions. 0 - 10V Fail FRÄNKISCHE...
  • Page 9: Standby Input

    If the system has been switched off over a longer period of time, this causes an increased risk of condensation in the pipes, and/or might lead to moisture damage in the building. 0 - 10V Fail FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 10: External Fan Activation Input

    The output can be used to externally display error messages and filter alarms. The output signal is 24 VDC. Elec. PH Filter Alarm Fail Alarm T1GTC 0 - 10V Hygro- stat Standby TFAH Switch FRÄNKISCHE MBA profi-air 180 flat connection box...
  • Page 11 In case of a warranty claim, the the manufacturer grants a warranty of claims can only be asserted for profi-air 180 flat connection box may 24 months from the time of comple- material and/or construction defects not be removed without the prior...
  • Page 12 Rooted in Königsberg – globally successful! Our facilities in Europe: Königsberg, Germany (headquarters) Bückeburg, Germany Schwarzheide, Germany Okříšky, Czech Republic St.-Leonards-on-Sea, Great Britain Moscow, Russia Yeles/Toledo, Spain Torcy-le-Grand, France Ebersbach/Fils, Germany Our facilities in Africa: Hermsdorf, Germany Ben Arous, Tunisia Mönchaltorf, Switzerland Casablanca, Morocco Milan, Italy...