FRÄNKISCHE profi-air 180 Flat Operating Instructions Manual

Advertisement

Quick Links

Wireless remote control for
profi-air
180 flat
®

Operating instructions

DRAINAGE SYSTEMS
ELECTRICAL SYSTEMS
BUILDING TECHNOLOGY
INDUSTRIAL PRODUCTS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the profi-air 180 Flat and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FRÄNKISCHE profi-air 180 Flat

  • Page 1: Operating Instructions

    Wireless remote control for profi-air 180 flat ® Operating instructions DRAINAGE SYSTEMS ELECTRICAL SYSTEMS BUILDING TECHNOLOGY INDUSTRIAL PRODUCTS...
  • Page 2: Table Of Contents

    Table of contents 1 General 1.1 Introduction 1.2 Safety 1.3 Symbols used 1.4 Intended use 1.5 Transport and unpacking 1.6 Checking the scope of delivery 1.7 Overview of functions 2 Layout of the wireless remote control 2.1 Front 2.2 Back 3 Putting the wireless remote control into operation 3.1 Installation of the antenna 3.2 Synchronisation...
  • Page 3: Introduction

    Its construction and design are state tions, warnings and notes of these damage to profi-air 180 flat. of the art and comply with all the operating instructions have to be Non-authorised changes or modifications of the wireless remote control are forbidden.
  • Page 4: Intended Use

    + alarm signal humidity in the extract air channel (with the humidity sensor installed in profi-air 180 flat) air quality in the extract air channel (with the VOC sensor installed in profi-air 180 flat) FRÄNKISCHE | OI profi-air RC 180 flat...
  • Page 5: Front

    2 Layout of the wireless remote control 2.1 Front Display Navigation button 2.2 Back Fastening points Open battery compartment Optional USB connection FRÄNKISCHE | OI profi-air RC 180 flat...
  • Page 6: Installation Of The Antenna

    Remove the housing cover of the ventilation unit. Screw the antenna to the connection coupling of the control board and turn it. For the position of the connection coupling, see profi-air 180 flat installation and operating instructions. Re-install the housing cover of the ventilation unit.
  • Page 7 4 Display overview Operating modes Operating data Info line Time/day Ventilation mode Navigation button The following table provides a short description of the different symbols and buttons of the wireless remote control. The wireless remote control features a power saving function which switches the display off between 11:00 pm and 07:00 am.
  • Page 8: Navigation Button

    5 Navigation button and keystroke combinations The following table provides an overview of the functions of the navigation button and the keystroke combinations. 5.1 Navigation button Button Function Push the “CENTER” button to start the user menu, select a menu item or confirm a setting. Push the “LEFT”...
  • Page 9: Operating Modes" Display Field

    6 User menu The user menu is used to control the profi-air 180 flat ventilation unit. It provides possibilities to set, e.g. operating modes and visualise operating data, filter replacement and error codes. The user menu is set up as follows:...
  • Page 10 Select the weekday by pushing the “UP” or “DOWN” buttons. Confirm this by pushing the “CENTER” button. For factory settings and setting options, see profi-air 180 flat installation and operating instructions, Section 5. For summer bypass, automatic mode and frost protection control strategies, see profi-air 180 flat installation and operating instructions, Section 6.
  • Page 11: Operating Data" Display Field

    Room temperature / measured at the wireless remote control Defroster heating (optional accessories required) Display with the profi-air defroster heating DN 125 in operation. For frost protection mode control strategies, see profi-air 180 flat installation and operating instructions, Section 6. Filter The triangles of the filter symbol show the remaining life of the filter.
  • Page 12 The drop symbol is active only if the ventilation unit is furnished with the optional humidity sensor. The automatic mode must be activated to control the air volume depending on the humidity. For automatic mode control strategies, see profi-air 180 flat installation and operating instructions, Section 6. Air quality (optional accessories required) The cloud symbol shows the air quality in the building.
  • Page 13: Info Line" Display Field

    The error code is displayed after the symbol. See Section 8 for a list of error codes. For more troubleshooting information, see profi-air 180 flat installation and operating instructions. Information regarding time setting, weekly programs, error codes, etc. is displayed here.
  • Page 14: Ventilation Mode" Display Field

    6 User menu 6.4 “Ventilation mode” display field This display field displays the current ventilation mode. Mode 0 The device is switched off. This function may only be used in exceptional cases, e.g unpleasant odour from outside. After activating mode 0, this will be enabled for 4 hours and switched to mode 3 afterwards. If the system has been switched off over a longer period of time, this causes an increased risk of condensation in the pipes, and/or might lead to moisture damage in the building.
  • Page 15 7 Fitter menu The fitter menu is used to commission the profi-air 180 flat ventilation unit. Push and hold the “RIGHT” button for 10 seconds to activate the fitter menu. The unit symbol starts flashing slowly and the control switches to ventilation mode 3. You can also access the fitter menu by pushing and holding the MANUAL and AUTO buttons at the control unit for 5 seconds.
  • Page 16: Sw Menu Item

    This menu item displays the automatic program and the target value for relative humidity. Display Description Operating modes The selected automatic program is displayed (only A1 available with profi-air 180 flat) display field You can set the humidity target value as follows: Step Description Push and hold the “RIGHT”...
  • Page 17: Defroster Heating Menu Item (Optional Accessories Required)

    Confirm this by pushing the “CENTER” button. Push and hold the “RIGHT” button for approx. 10 seconds to end the fitter menu. For defroster heating control strategies, see profi-air 180 flat installation and operating instructions, Section 6. 7.5 Summer bypass menu item...
  • Page 18: Target Values And Setting Ranges

    Confirm this by pushing the “CENTER” button again. Push and hold the “RIGHT” button for approx. 10 seconds to exit the fitter menu. For summer bypass control strategies, see profi-air 180 flat installation and operating instructions, Section 6. 7.6 Target values and setting ranges The following table shows the target values and setting ranges which can be adapted using the wireless remote control.
  • Page 19 Fresh air temperature < –13 °C Supply air temperature < 5 °C Fire protection; one sensor measures a temperature > 70 °C Communication error For more troubleshooting information, see profi-air 180 flat installation and operating instructions. FRÄNKISCHE | OI profi-air RC 180 flat...
  • Page 20: Weekly Program P1

    9 Weekly programs Weekly program P1 Monday – Friday Time / mode Weekend Time / mode Weekly program P2 Monday – Friday Time / mode Weekend Time / mode Weekly program P3 Monday – Friday Time / mode Weekend Time / mode FRÄNKISCHE | OI profi-air RC 180 flat...
  • Page 21: Weekly Program P4

    9 Weekly programs Weekly program P4 Monday – Friday Time / mode Weekend Time / mode Weekly program P5 Monday – Friday Time / mode Weekend Time / mode Weekly program P6 Monday – Friday Time / mode Weekend Time / mode FRÄNKISCHE | OI profi-air RC 180 flat...
  • Page 22: Weekly Program P7

    9 Weekly programs Weekly program P7 Monday – Friday Time / mode Weekend Time / mode Weekly program P8 Monday – Friday Time / mode Weekend Time / mode Weekly program P9 Monday – Friday Time / mode Weekend Time / mode FRÄNKISCHE | OI profi-air RC 180 flat...
  • Page 23: Weekly Program P10

    9 Weekly programs Weekly program P10 Monday – Friday Time / mode Weekend Time / mode Weekly program P11 No definite time is specified in weekly program P11. FRÄNKISCHE | OI profi-air RC 180 flat...
  • Page 24 Rooted in Königsberg – globally successful! Our facilities in Europe: Königsberg, Germany (headquarters) Bückeburg, Germany Schwarzheide, Germany Okříšky, Czech Republic St.-Leonards-on-Sea, Great Britain Moscow, Russia Yeles/Toledo, Spain Torcy-le-Grand, France Our facilities in Africa: Ebersbach/Fils, Germany Ben Arous, Tunisia Hermsdorf, Germany Casablanca, Morocco Mönchaltorf, Switzerland Milan, Italy...

Table of Contents