Removing and replacing the front bezel

To access some server components, or field replaceable units (FRUs), you
must first remove the front bezel. Replace the bezel after the part
replacement is complete.

Bezel removal

The server bezel is held onto the server chassis through a friction fit onto
four retention posts, which are mounted to the chassis along the left and
right edges of the chassis. There are no screws or other fasteners.
Procedure
1.
2.

Replacing a fan

Fans provide for front-to-back airflow to be consistent with other storage
system components. The server continues to operate following the failure of
a single fan and during the temporary removal of a fan for replacement. A
failed fan must be replaced as soon as possible.
The fans are contained within three assemblies, which are located behind the
front fascia and are removable from the front of the server. All servers have
three fans (one fan per assembly).
The server's cooling airflow enables the system to operate in an ambient
temperature range of 10°C to 35°C when mounted in a storage cabinet with
associated components required to make up a storage system. The storage
system administrator is responsible for ensuring that the ambient
temperature within the rack does not exceed the 35°C operating limit.
50
Figure 10 Server front bezel with grasping areas
To remove the bezel, grasp the front of the bezel by the grasping areas.
Gently pull the bezel straight out away from the server.
Replacing server components
Hitachi NAS Platform 3080 and 3090 G1 Hardware Reference