REMOTE INPUT CALL KEYS

The E-2010 may be activated from four
remote inputs. The typical remote input
circuit is shown. A contact closure, capable
of sinking at least 10 mA, will activate the E-
2010. The closure must remain active for a
minimum of 1/2 a second.
The remote input activates Call Keys #57,
#58, #59 or #60. These Call Keys are
programmed just like Call Keys 1-56, as
previously described.

TIME-OF-DAY (Automatic) CALL KEYS

There are two Call Keys that will automatically activate based on the day of the week and the time of the
day. Refer to Auto Call Setup for more information.
These Call Keys are #61 and #62. These Call Keys are programmed just like Call Keys 1-56, as
previously described.
NOTE:
Any active Call Key may be terminated by pressing CALL KEY
CANCEL. The E-2010 will return to the standby screen.
00 = Cancel
01 = Wail
02 = Attack
03 = Alert
04 = Public Address
05 = Air Horn
06 = Hi-Lo
07 = Whoop
08 = Noon Test

COMMAND NUMBER TABLE

49 = Voice Message 1
50 = Voice Message 2
51 = Voice Message 3
52 = Voice Message 4
53 = Voice Message 5
54 = Voice Message 6
55 = Voice Message 7
56 = Voice Message 8
59 = Voice Message 9
60 = Voice Message 10
61 = Voice Message 11
62 = Voice Message 12
17 = Voice Message 13
18 = Voice Message 14
19 = Voice Message 15
20 = Voice Message 16
12V
330
09 = North
10 = East
11 = South
12 = West
13 = Clockwise
14 = Counter Clockwise
21 = Rotor Position
10
CONTACT+
560
CONTACT-
18 Volt
Clamp
15 = Silent Test
63 = Active Status
30 = Test Clear
57 = Strobe On
58 = Strobe Off
37 = Strobe Test
22 = Counter
23 = Counter Clear
24 = Arm
25 = Dis-Arm
26 = Siren On
27 = Siren Off
28 = S/N Request
29 = S/N Status
31 = Status Request
33 = Battery/AC
34 = Battery/Temperature
35 = Instant Status

Hide quick links: