Download Print this page

Specifications - State Water Heaters 305 Exterior Specification Sheet

State water heaters gas-fired water heaters specification sheet

Advertisement

Model
Minimum Gas Consumption Btu/h
Maximum Gas Consumption Btu/h
Hot water capacity (Min - Max) *
Interior Hot Water Capacity (45° rise)
Exterior Hot Water Capacity (45° rise)
Default Temperature Setting (no controller)
Temperature Controller Default Temperature
Setting
Maximum Temp Setting (Commercial**)
Maximum Temp Setting (Residential)
Minimum Temperature Setting
Weight (Indoor/Outdoor)
Efficiency Rating / Energy Factor
Noise level
Normal (Indoor/Outdoor)
Electrical
Standby
Consumption
Anti-frost Protection
By-Pass Control
Natural Gas
Minimum Gas Supply
Pressure
Propane
Natural Gas
Maximum Gas Supply
Pressure
Propane
Type of Appliance
Operation
Approved Gas Type
Connections
Ignition System
Electric Connections
Water Temperature Control
Water Suppl Pressure
y
Maximum Water Supply Pressure
Temperature Control Cable
Energy Star® Qualified
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
** for commercial and hydronic applications requiring higher temperatures
Specifications are subject to change without prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.
For more information on State On-Demand Water Heaters, contact:
State Water Heaters
500 Tennessee Waltz Parkway
Ashland City, TN 37015
800-365-0024 Toll-free USA
www.statewaterheaters.com

Specifications

305
505
200/201 Series
200/201 Series
15,000
199,000 Natural Gas
180,000
190,000 Propane Gas
0.6 - 7.5 GPM
0.6 - 9.4 GPM
(2.3 - 28.4 L/min)
(2.3 - 35.5 L/min)
7.4 GPM (28.0 L/min)
Natural Gas
6.6 GPM (25.0 L/min)
7.1 GPM (26.9 L/min)
Propane Gas
6.6 GPM (25.0 L/min)
7.4 GPM (28.0 L/min)
120º F (49º C)
104º F (40º C)
160º F (71º C)
Selectable at 120º F (49º C) or at 140º F (60º C)
98º F (37º C)
Indoor Unit 50 lb (23kg) Outdoor Unit 46 lb (21 kg)
84% / .82 E.F.
49dB
65 W/50 W
79 W/55 W
2 W
100 W
Fixed
5.0 inch W.C.
8.0 inch W.C.
10.5 inch W.C.
13.5 inch W.C.
Direct Vent, Temperature controlled continuous flow gas hot water system.
With or without temperature controls, mounted in kitchen, bathroom, etc.
Natural Gas or Propane - Ensure unit matches gas type it's being installed on.
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4"
Direct Electronic Ignition
Appliance: AC 120 Volts, 60Hz. Temperature Control: DC 12 Volts (Digital)
Simulation Feedforward and Feedback.
Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum
performance)
150 PSI
Non-Polarized Two Core Cable (Minimum 22 AWG)
Yes
Yes
April 2010R
705
19,000
237,000
0.6 - 9.8 GPM
(2.3 - 37 L/min)
8.8 GPM (33.5 L/min)
8.7 GPM (33.1 L/min)
185º F (85º C)
140º F (60º C)
55 lb (25 kg)
84%/N.A.
99 W/72 W
116 W
Electronic
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0.0
No
ANSZ21.10.3
CSA 4.3
705
505
305
0
25
50
75
100
delta T - Temperature Rise (ºF)
SRGSS02007
125
150

Advertisement

loading

This manual is also suitable for:

305 interior505 exterior505 interior705705 interior305 200 series ... Show all