Gira Alarm Connect Quick Start Manual page 7

Hide thumbs Also See for Alarm Connect:
Table of Contents

Advertisement

Quick start guide — Configuration in GPA
Locate other
devices
Project is
configured. What
do I do now?
Naming devices
In order to facilitate subsequent identification of the device used, the device name assigned
to the device in the device catalog should be changed to a unique device name.
The device name entered in the "Name" field is displayed on the info page of the wireless
operating unit (example: "Magnetic contact kitchen window open" instead of "Magnetic
contact open").
9. Insert the wireless operating unit into the project.
Bibliothek
Gebäude
Geräte
Neu gefundene Geräte
Zugeordnete Geräte
GWA
Gira Alarm System 2.0.7
Geräte-Katalog
Gira Alarm System 2.0.7
GWA
Verfügbare Komponenten
Funk Magnetkontakt
Funk Technikkontakt
Funk Bewegungsmelder
Funk Bewegungsmelder mit Kamera
A
Funk Glasbruchsensor Aufputz
Funk Glasbruchsensor Unterputz
Funk Bedieneinheit
Funk Innensirene
Funk Außensirene
I / O
Funk I/O-Modul
Funk Handsender
A: Select and locate the wireless operating unit from the device catalog.
B: Change the device name if desired
C: Enter the hardware ID. The hardware ID is located on each device label as well as on two
loose labels included with each device. You can scan the hardware ID with an appropriate
scanner and enter it in the GPA.
D: Deactivate the checkbox under "Operating unit is connected to external power supply".
Battery operation is sufficient for the functional test.
10.Enter the wireless magnetic contact in the project.
Library
Building
Devices
New devices found
Assigned devices
Gira Alarm System 2.0.7
HWS
Device catalog
Gira Alarm System 2.0.7
HWS
A
Available components
Wireless magnetic contact
Wireless technical contact
Wireless motion detector
Wireless motion detector with camera
Wireless glass-breakage sensor, surface-mounted
Wireless glass-breakage sensor, flush-mounted
Wireless operating unit
Wireless indoor siren
Wireless outdoor siren
I/O
Wireless I/O module
Wireless hand-held transmitters
A: Select and locate the wireless magnetic contact from the device catalog.
B: Change the device name if desired.
C: Enter the hardware ID.
11.Commissioning the GPA project (transfer to the alarm control unit memory).
• Click on
Commissioning
Inbetriebnahme
Gira Sicherheitssystem...
Online
IP: 192.168.111.111
• Click on
Start commissioning
status of the transfer is indicated by the progress bar. Depending on the project size, the
transfer can take up to five minutes.
12.After successful commissioning of the project, a timestamp appears under "Last
commissioning".
13.Put the wireless operating unit and the wireless magnetic contact into commission.
Etage
Eigenschaften
Allgemein
Raum
1
Name
Funk Bedieneinheit
1
Kategorie
Funk
Gira Alarm
Komponente
Bedieneinheit
System
Hardware-ID
61-00999
Sicherungsbereich
Sicherungsbereich 1
Zusätzliche Optionen
Türmodul-Funktion
(Funktion ist nur bei aktivierter
Zwangsläufigkeit verfügbar)
Bedieneinheit is an Stromversorgun...
Storey
Features
General
Room
1
Name
Wireless magnetic contact
1
Category
Wireless
Wireless
Gira
Components
security sstem
operating unit
magnetic cont...
Hardware ID
01-00001
Security area
Security area 1
Alerting
Triggering contact
Only use internal magnetic contact...
Internal magnetic contact and external...
Use external contact only
Device is armed for
Internally and externally armed
Externally armed
Device with gateway function
Door chime
: The next window opens.
Appliaktionsdaten löschen
Inbetriebnahme starten
Projektkopie auf Gerät sichern
: Transfer the project to the alarm control unit Connect memory. The
B
C
D
B
C
Letzte Inbetriebnahme
7

Advertisement

Table of Contents
loading

Related Products for Gira Alarm Connect

Table of Contents