Download Print this page

General Information; Installation - Novy 7550 Operating And Installation Instructions

Advertisement

GENERAL INFORMATION

General
These are the mounting instructions for the Novy unit shown on the cover. The user manual is delivered separately with
this unit. Carefully read these instructions before installing and commissioning this unit. It is recommended to have one
or more qualified persons carry out the installation.
This manual makes use of a number of symbols. The meaning of these symbols are given below.
Symbol
Safety
Observe the following mounting and safety tips for mounting:
• The installation and electrical connection of the unit shall be carried out by an authorised expert. The manufacturer
does not accept any responsibility for any damage resulting from faulty building in or connection.
• Carefully take the unit from the packaging and check it for damage before mounting. Do not mount the unit in case of
any damage.
• Check if all mounting materials have been supplied using the drawings in section 2.2.
• The unit is intended for household use only (preparation of food) excluding any other domestic, commercial or indus-
trial use.
• Position the electrical connection such, that it is located in the cabinet in which the cooking unit is mounted
• The hood does not have an on/off switch. For this reason the fixed wiring is to be provided with a circuit breaker (double
pole switch or safety switch with a minimum contact distance of 3 mm).
• Safety can only be guaranteed if the unit is connected to an earth wire in accordance with the required regulations.
• Do not use an extension cord for connecting to the electricity grid.
• Replace defective or damaged parts only with original Novy parts.
• Replace a damaged power cable with an original Novy power cable.
Important before mounting
Page 2 of these mounting instructions show the mounting drawings. Observe the following mounting tips before starting
the mounting activities:
• For easier mounting of the ceiling unit, it is recommended to do this with at least 2 persons.
• Make sure that the ceiling has sufficient load bearing capacity.
InTouch
InTouch offers the option to control the Novy cooker hood from the Novy InTouch induction hotplate. The hood may, as
a default, be combined with InTouch induction hotplates. Visit the website for the different models of induction hotplates
with InTouch.

INSTALLATION

Follow the mounting drawings on page 2.
1.
Do NOT remove the hood from the packaging. The hood is mounted with the box.
When the hood has been completely mounted at the optimum distance, the box can be removed from the hood.
2. Attaching the mounting plates:
- Take the drilling jig from this mounting instruction (see the centre page of this booklet).
- Cut the drilling jib in half as indicated.
- Mark the central line of the drilling jigs. Make sure that the hood is mounted in the centre over the cooking plate.
- The distance between the centres of both mounting plates is 840 mm (or 420 mm measured from the central line).
- Mark the 4 drilling holes on each mounting plate.
In view of the substantial own weight of the hood, the ceiling must have sufficient load bearing capacity.
Bear in mind that the electrical connection must be placed behind the right-hand mounting plate.
Meaning
Indication
Warning
Action
Explanation of an indication on the
hood
This symbol indicates an important tip
or a dangerous situation.
EN 14

Advertisement

loading