Machine Operating Cycle - Pro Mach Wexxar BEL Series Operation & Service Manual

Semi-automatic case former and packing station
Table of Contents

Advertisement

B E L 5 0 5 / 5 0 5 S S
M
O
ACHINE
PERATING
1.
The bottom edges of the major flaps depress the actuators of the two "floor" switch valves and
the side of the case depresses the wheeled "body" switch valve. All three switches must be
actuated for the machine cycle to start.
2.
The two small levers of the major (side) flap openers momentarily open the bottom major flaps
wider to clear the minor (end) flaps.
65-11-7 2/5/2007
- A
E M I
U T O M A T I C
C
YCLE
C
F
& P
A S E
O R M E R
Bottom major flap
opener
S
A C K
T A T I O N
"Body" switch
"Floor"
switches
1 2