Linde LIV IQ Manual

Linde LIV IQ Manual

Integrated valve with digital display – portable, delivery system for medicinal oxygen.

Advertisement

Manual.
LIV® IQ Linde Integrated Valve with digital display
– portable, delivery system for Medicinal Oxygen.
Linde: Living healthcare

Advertisement

Table of Contents
loading

Summary of Contents for Linde LIV IQ

  • Page 1 Manual. LIV® IQ Linde Integrated Valve with digital display – portable, delivery system for Medicinal Oxygen. Linde: Living healthcare...
  • Page 2 Manual – LIV® IQ Oxygen This manual was last revised: July 2015 ® LIV is a registered trademark of The Linde Group.
  • Page 3: Table Of Contents

    Manual – LIV® IQ Oxygen Contents. 1. Introduction 2. Device Description 3. Intended Use 4. Safety Requirements 5. Operating Instructions 6. MR Compatibility 7. Cleaning 8. Service and Maintenance 9. Fault – Cause – Remedy 10. Storage and Recycling 11. Contact Information...
  • Page 4: Introduction

    Risk of severe injury or damage to persons or property. 3. Intended Use. The LIV IQ is suitable for use in all healthcare settings including, but not limited to, hospital, out - patient, imaging center and ambulatory healthcare. The pressure regulator integrated in the cylinder...
  • Page 5: Safety Requirements

    Do not expose to corrosive substances e.g. ammonia. → Keep the LIV IQ at a minimum distance of 12 inches (30 cm) from the magnet opening, during use in MRI environment. → Keep out of reach and sight of children.
  • Page 6: Operating Instructions

    The delivery device hose is firmly attached. → Make sure that the probe connector is compatible with the respective Push delivery device hose onto the flow outlet of the LIV IQ and make medicinal gas. sure that it is firmly attached before opening the shut-off valve.
  • Page 7 Digital display, 5) – additional information If no lines or numbers are visible around the content indicator, do not use the product. Mark it as defective and contact Linde Healthcare. The digital display has a number of elements and audible alerts that communicate the status of the LIV IQ: Full ¾...
  • Page 8: Mr Compatibility

    6. MR Compatibility. The LIV IQ products include aluminum cylinders, regardless of cylinder size The LIV IQ must not be brought any nearer than 30 cm from the opening of and contents. Aluminum cylinders have no magnetic parts. the magnet. Do not move the package during MRI scan, as the MR image quality can be degraded.
  • Page 9: Fault - Cause - Remedy

    Shut-off valve is difficult to turn and cannot Valve too firmly opened or closed. Verify direction of rotation using a flow test. If there is a flow, be opened/closed without applying turn hand wheel to “OFF”. Alternatively, contact Linde significant force. Healthcare. 1. Shut-off valve is closed.
  • Page 10 Put the product in a well-ventilated area and contact Linde Healthcare. 1. Two devices draw gas 1. Press and hold the mute button for three seconds.
  • Page 11: Storage And Recycling

    Emergency Services should be advised of the location of the cylinder store. Do not stack LIV IQ packages on top of each other as this can cause damage to the valve or the handling device.
  • Page 12 Linde Gas North America LLC 575 Mountain Ave, Murray Hill, NJ 07974 Phone (866) 543-3427, www.linde-healthcare.us...