5 Boiler Installation Sequence

5 Boiler Installation Sequence

5.1 General

Preparation of boiler location
Clearances required
Mount the boiler on a flat and vertical area of wall of
sufficient area for the boiler plus the required clearan-
ces for installation and servicing.
The clearances are as detailed below and are shown on
the installation template supplied with the boiler:
- 150 mm below the boiler
- 5 mm on either side of the boiler
- 210 mm on top of the boiler
- 500 mm in front of the boiler*
* Clearance is only required to enable easier access to
the boiler for servicing and may be provided by an
openable door, etc.
Note!
If the boiler is to be fitted in a timber framed
building, it should be fitted in accordance with
Institute of Gas Engineers Publication
IGE/UP/7/1998 „Guide for Gas Installations in
Timber Framed Dwellings".
440
I
60
30
90
0
120
°C
bar
4
0
0
3
1
2
Fig. 5.1: Dimensions of boiler
12
5
Fig. 5.2: Free space required for installation
Selecting position of boiler
Refer to „Boiler location" for information regarding sit-
ing the appliance. In general the boiler must be positio-
ned such that.
• There is adequate space around the boiler for service
and maintenance.
• The boiler can be correctly flued, i.e. the flue terminal
position is sited in accordance with the flue terminati-
on section and the air/flue duct can be installed in
800
accordance with the flue installation instructions sup-
plied.
• All necessary pipework can be connected, including
the pressure relief valve.
338
200
5
I
60
30
90
0
120
°C
bar
4
0
0
3
1
2
150
Note!
Should it be necessary to run system pipework
to above the boiler within the width of the
casing, use the optional top connection acces-
sory (Art.No. 306 251).
Instructions for Installation and Servicing turboMAX pro R3