Rev. 02/01/18 VER SMS-IMATE-II 20140828-EN USER MANUAL iMate-II Endo Motor *The unit must be installed by a qualified engineer. *Only for user by dental professionals. *Read this manual carefully before installation or operation.
Rev. 02/01/18 VER SMS-IMATE-II 20140828-EN CONTENTS SECTION 1: GENERAL INTRODUCTION SECTION 2: MAIN TECHNICAL INDEX SECTION 3: SYMBOL SECTION 4: PRODUCT STRUCTURE SECTION 5: OPERATION PANEL AND LCD SCREEN SECTION 6: OPERATION SECTION 7: NOTICE SECTION 8: TOUBLESHOOTING SECTION 9: MANTENANCE & SERVICE...
Page 3
Thank you for purchasing our device. Before operating the device, please fully read the manual and this manual should be saved for later use. DENJOY DENTAL CO., LTD will take the responsibility for the security, reliability, capability under the following conditions: 1. The installation, debugging, maintenance should be adjusted by the approbatory technician by our company or obtained related nation quality level license professions.
VER SMS-IMATE-II 20140828-EN CONTACT INFORMATION The device is manufactured by: DENJOY DENTAL CO., LTD Address: F4, Building A4, Lugu Medical Device Park, No.229 Guyuan Road, Changsha, 410205 P. R. China Authorized European Representative: Company name: LANDLINK GMBH Address: DORFSTRASSE 2/4, EMMENDINGEN, 79312...
Page 5
VER SMS-IMATE-II 20140828-EN root-canal treatment based on the micro-electronic control technology. Cordless endo motor can be held in hand to operate and cordless charging. This unit contributes to alleviate the dentist’s working intensity. Product application and intended use Cordless Endo Motor is applied to dental especially endodontic treatment.
Page 6
VER SMS-IMATE-II 20140828-EN and reverse mode can not be changed. Under P6, when the torque exceeds 3.0N.cm, reciprocating rotation will stop. (Remarks: Mini 16:1 contra-angle is a standard part of iMate-II.) 3. Auto-reverse and auto-stop function: When torque exceeds the upper limit, the motor will automatically reverse or stop.
VER SMS-IMATE-II 20140828-EN SECTION 2: MAIN TECHNICAL INDEX Model Name: iMate-II Trade Name: Type of protection against electric shock: Class II equipment: Degree of protection against electric shock: Type B applied part: Degree of protection against ingress of water: IPX0...
Page 8
VER SMS-IMATE-II 20140828-EN Consult accompanying documents Cautions Authorized Representative in the European Community CE Mark: conforms to essential requirements of the Medical Device Directive 93/42/EEC. Date of manufacture. Manufacturer Specifies serial number Type B applied part Refer to instruction manual / booklet...
VER SMS-IMATE-II 20140828-EN DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. alert indicator displayed on the LCD screen Battery power sign displayed on the LCD screen AUTO REVERSE: If the load is removed after auto reverse rotation, it returns to the normal rotation again.
Page 10
VER SMS-IMATE-II 20140828-EN 1. Mini 16:1 Contra-angle 2. Motor handpiece 3. Charging Base SECTION 5 OPERATION PANEL AND LCD PANEL...
Page 12
VER SMS-IMATE-II 20140828-EN POWER ● Holding down the POWER key for more than one second turns on the power and the LCD panel lights. ● Holding down the POWER key for more than one second while the power is on turns off the power and the LCD display turns off.
Page 13
VER SMS-IMATE-II 20140828-EN Holding down the PROGRAM key for more than one second choose program number. The following parameters can be set. Torque, Gear ratio, Speed and Auto reserve. Press PROGRAM key can memorize the parameters setting. UP/DOWN To adjust the set value for each parameter Speed: rpm, Torque: N.cm...
Page 14
VER SMS-IMATE-II 20140828-EN means program 1, 2, 3, 4,5, 6. 6 different programs can be preset and saved according to the requirement of the operator. P6 is special program for reciprocating rotation mode and the mark “ ” can be seen on the LCD.
Page 15
VER SMS-IMATE-II 20140828-EN means speed of 550 rpm. means torque of 2.0. means reverse setting means battery remaining AUTO REVERSE The present auto reverse mode mark is displayed. :AUTO REVERSING (If the load is removed after auto reverse rotation, it returns to the normal rotation again.)
Page 16
VER SMS-IMATE-II 20140828-EN displayed regardless of the ON or OFF position of the power. The mark will be animated when the batteries are being charged. :Means full charge :Means appro. 30-80% remains : Means less than 30% : Means low voltage. Charge immediately...
VER SMS-IMATE-II 20140828-EN SECTION 6: OPERATION 1, Charge A, connect the power adapter to the charging base. B, Put the main unit on the charging base, during this period, please confirm if a beep is heard and the power display is flashing, and shows “...
Page 18
VER SMS-IMATE-II 20140828-EN Note: While uninstall the file, please turn off the power. While install the file, please double confirm the file has been successfully loaded. Please keep the file clean, dirty file can cause the vibration during the operation.
VER SMS-IMATE-II 20140828-EN Program memory setting. Because last time you already saved the program setting, this program setting will remain the same until you change the program and save again. SECTION 7: NOTICE Note: Please do not use improper file because it will cause accident during operation.
VER SMS-IMATE-II 20140828-EN interference other equipment Forbidden The cardiac pacemaker patient can not use this product. Do not use with high-frequency surgical equipment and heart disease in patients with caution! The machine can only be used independently; please do not connect the machine with other products.
Page 21
VER SMS-IMATE-II 20140828-EN The adapter didn’t connect well. battery Please recheck the connection can’t The major machine didn’t put on the charger charged. base correctly. Please recheck the connection The battery is broken. Contact with your dealer Fault Function Description...
VER SMS-IMATE-II 20140828-EN Relief Measures : For all the fault codes , please press any button to eliminate fault code except the POWER. SECTION 9: MANTENANCE 1) Please recharge the battery for 5 minutes each month and check the machine everything in order too.
VER SMS-IMATE-II 20140828-EN Remarks: Please autoclave Mini 16:1 contra-angle only. Because the high temperature disinfection stand is close to the bottom of the heat source, the local temperature will be very high, so put the vessel in the middle or upper part of the disinfection cabinet.
VER SMS-IMATE-II 20140828-EN without poor ventilation. Transportation is applicable to all common method. Section 12: Packing List Endo Motor iMate-II includes: Motor handpiece 1 pc Charging base 1 pc Mini 16:1 contra-angle 1 pc Adapter 1 pc Motor cover 1 pc...
Page 25
VER SMS-IMATE-II 20140828-EN Products warranty or service will not be extended if (1) the product is repaired, modified, misused, disassembled, or using the parts are not provided by the manufacturer, (2) The serial number of the product is defaced or missing.
Page 26
VER SMS-IMATE-II 20140828-EN Table 1 Guidance and manufacturer’s declaration - electromagnetic emissions The [iMate-Ⅱ] is intended for use in the electromagnetic environment specified below. The customer or the user of the [iMate-Ⅱ] should assure that it is used in such an...
Page 27
VER SMS-IMATE-II 20140828-EN 61000-3-3 equipment/system is intended for use by healthcare professionals only. This equipment/ system may cause radio interference or may disrupt the operation of nearby equipment. It may be necessary to take mitigation measures, such as re-orienting or relocating the [iMate-Ⅱ] or shielding the...
Page 28
VER SMS-IMATE-II 20140828-EN (ESD) ±8 kV air ±8 kV air concrete ceramic tile. If 61000-4-2 floors covered with synthetic material, relative humidity should be at least 30 % Electrical ±2 kV for ±2 kV for Mains fast power power power...
Page 29
VER SMS-IMATE-II 20140828-EN before installation. Mains filter is required, if necessary. Surge ±1 ±1 Mains power line(s) line(s) quality should 61000-4-5 line(s) line(s) be that of a ±2 typical line(s) commercial or earth hospital environment. Voltage <5% U <5% U...
Page 30
VER SMS-IMATE-II 20140828-EN <5% U <5% U the [iMate-Ⅱ] (>95% dip (>95% dip be powered in U in U from an for 5s for 5s uninterruptible power supply or a battery. Power 3 A/m 3 A/m Power frequency frequency (50/60Hz)
Page 31
VER SMS-IMATE-II 20140828-EN Immun Complia Electromagnetic ity Test 6060 environment - guidance level Test level Portable and mobile RF communications equipment should be used no closer to any part of the [iMate-Ⅱ], including cables, than the recommended separation Conduc 3Vrm...
Page 32
VER SMS-IMATE-II 20140828-EN where p is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m) Field strengths from fixed RF transmitters, as determined by an...
Page 33
VER SMS-IMATE-II 20140828-EN Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered.
Page 34
VER SMS-IMATE-II 20140828-EN output power of the communications equipment. Rated Separation distance according to maximum frequency of transmitter output power of 150 kHz to 80 80MHz to 800MHz transmitte 800MHz 2.5GHz d=1.2 d=1.2 d=2.3 0,01 0.12 0.23 0.38 0.73 For transmitters rated at a maximum output power not...
Page 35
VER SMS-IMATE-II 20140828-EN WARRANTY REGISTRATION FORM Item Name: Model Name: Serial No.: Date of Purchase: Name: Address: Phone: Email: Name of Distributor: Authorized Distributors: Stamp and Signature...
Need help?
Do you have a question about the iMate-II and is the answer not in the manual?
Questions and answers