Download Print this page

Key Index - Maytag 11 Series Technical Information

Electric freestanding range
Hide thumbs Also See for 11 Series:

Advertisement

Control Testing Procedures
To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless
testing requires power.
Feature
H1 Control Panel Assembly Matrix
Clean
Delay
Broil
Convect
Roast
Cook &
Oven
Timer
Hold
Bake
Light
Keep
Warm
Convect
Bake
CANCEL
Clock
Favorite
H1 Control: Relay Logic
June 2006
© 2006 Maytag Services
!
Procedure
Continuity is indicated as follows:
1000 – 6600 Ω for Cancel pad.
1000 – 15000 Ω for All other pads.
16
Autoset
9
8
1
COOKING MODE
IDLE
BAKE PREHEAT
BAKE
BROIL PREHEAT
BROIL
CLEAN PREHEAT
CLEAN
KEEP WARM
CONVECT BAKE PREHEAT
CONVECT BAKE

KEY INDEX

- OFF
- ON
- ON OR OFF (DETERMINED BY USER INPUT)
- TEMPERATURE CONTROLLED
WARNING
Pad
1
2
3
4
5
6
7
8
9
0
Cancel
Clock
Cook & Hold
Broil
Bake
Convect Bake
Convect Roast
Clean
Keep Warm
Favorites
Timer
Light
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
5
Results
Trace
Measurement
13 & 15
Continuity
12 & 13
Continuity
12 & 15
Continuity
4 & 14
Continuity
4 & 12
Continuity
4 & 10
Continuity
5 & 13
Continuity
5 & 12
Continuity
5 & 10
Continuity
10 & 12
Continuity
1 & 2 or 1 & 3
Continuity
4 & 5
Continuity
4 & 7
Continuity
5 & 7
Continuity
10 & 11
Continuity
4 & 13
Continuity
7 & 14
Continuity
7 & 15
Continuity
11 & 12
Continuity
13 & 14
Continuity
5 & 14
Continuity
7 & 13
Continuity
r
r
r
r
r
r
r
r
r
r
16027229
Replaces 16026900

Advertisement

loading