Linked or Separate Selection

By default a dual station pair of DS41 instruments
automatically keep the following settings the
same in both instruments:
Alarms On/Off
Alarm Values (Deep and Shallow)
Keel Offset (see note)
Units of measure (see note)
Example: Switching an alarm off on the slave
instrument will also switch the alarm off on the
master instrument. The reverse also applies,
alarms changed on the master will be
automatically changed in the slave instrument.
Note: The keel offset and units of
measure should only be changed on
the Master instrument.
If independant settings are required the link
feature can be disabled.
To enable or disable the linked mode:
1. Apply power while holding down the # key.
ON
^
Hold down during power up
2. When the unit is on. The display will first
indicate the current display unit:
3. Continue to hold the # key. The display
will indicate the current master/slave
selection.
OFF
OFF
V V
Example
Slave
4. Continue to hold the # key until the
display indicates the current linked/
separate selection.
Separate
5. Use the " and # keys to change the
selection.
6. To exit this mode, press and hold both the
" and # keys simultaneously.
Alternatively, if no keys are pressed for a
period of 5 seconds normal depth display
will commence.
ON
ON
^ ^
Press simultaneously
This setup procedure applies to
the master device and all slave devices.
For separate operation all devices,
including the master, must be set to
Separate mode. Also, for linked operation
all devices, including the master, must be
set to Linked mode.
Linked
OFF
OFF
V V