PUREGAS, LLC
10.3 8,000 Hour Maintenance
Under typical operating conditions:
8,000 hours of run time will occur between one (1) and two (2) years of use.
This will be identified by a TTL TIME Alarm on the display.
MODEL:
SERIAL NUMBER:
DATE INSTALLED:
Procedure
Install 8,000 Hour Maintenance Kit
Read & Record Flow Rate (FLOW)
Measure & Record
Compressor Amp Draw
Set System Pressure (50 PSI)
Set Static Pressure (17 PSI)
Set Outlet Pressure
Test Consistent Heatless Dryer Cycling
Test Compressor ON/OFF Cycling
Test Air Fittings for Leaks
Reset TTL TIME Reading to Zero
Visually Inspect Inside & Outside of Unit for Loose
Wiring or Hardware
NOTE: COPY OR PRINT THIS PAGE AND KEEP IT WITH THE AIR DRYER
LOCATION NAME:
ADDRESS:
Section
11.4
8.5.5.2
9.2
8.8
8.10
8.11
9.6
9.10
9.15
8.7.6
Maintenance Performed by:
Date of Maintenance:
Page 77 of 99
P550W Series Air Dryers User's Guide
Maintenance Interval (Hours)
8,000
16,000
24,000
P011658 – Rev. P
32,000
40,000