5.5 Dryer Function Overview
#
Component
1
Compressor
2
Heatless Dryer
3
Unloader Valve
4
Capacity Control Valve
5
Humidity Sensor
6
Air Tank
7
Static Pressure Regulator
8
Flow Block
9
Outlet Pressure Regulator Regulates the Outlet Pressure.
10
Pressure Outlet
11
4-Bank Outlet Manifold
P550W Series Air Dryers User's Guide
Description
Compresses drawn in ambient air.
Removes moisture from compressed air.
Relieves excess Compressor head pressure.
Regulates System Pressure and prevents air from
bleeding back through the Heatless Dryer.
Measures the Humidity of the compressed air.
Stores dry compressed air.
Regulates the Static Pressure (17 PSI).
Maintains constant pressure on the Flow Block
for accurate Flow measuring.
Measures the Flow of compressed air.
Outputs the pressure set by the Outlet Pressure
Regulator.
Distributes the air into 4 separate outlets.