Cableado De La Chimenea - Empire Comfort Systems Boulevard VFLL60FP90LP-1 Manual

Contemporary linear vent-free gas fireplace
Table of Contents

Advertisement

Available languages

Available languages

FIREPLACE WIRING
WIRING DIAGRAM
IGNITOR
SENSOR
CPI/IPI
PILOT
SWITCH
GREEN
BLUE
BLUE
ORANGE
WHITE
WHITE
REMOTE RECEIVER
YELLOW
+ ON
REMOTE
- OFF
EXTENSION HARNESS
BLACK
BLACK
NOT USED
GAS CONTROL
VALVE
(GND)
AC/DC
POWER ADAPTOR
ELECTRONIC
CONTROL MODULE
NOT USED
The wire terminals shown in Figure 52 are not connected.
If any of the original wire as supplied with this unit must be
replaced, it must be replaced with factory replacement parts.
CAUTION
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.