ring RSC404 Instructions Manual page 6

Intelligent battery charger 6v/12v 4a. suitable for 12v lead acid, gel, calcium, agm and efb batteries between 10-120ah
Hide thumbs Also See for RSC404:
Table of Contents

Advertisement

CHARGING
NOTE: Before using the charger, please review all safety and connection directions. Failure to do so can damage battery
and cause serious injury or death.
·
Connect the charger to battery per the operating instructions.
·
Connect the charger to AC outlet.
·
Select the appropriate charging mode for your batteries.
·
If the charger does not detect a properly connected battery, the Reverse Polarity Indicator LED will light or the Error Code will
appear on LCD display until such a battery is detected. Charging will not begin while the Reverse Polarity Indicator LED is on or
the error code disappears. When the charging begins, the charging process Icon on LCD display will appear.
·
When charging is completed, unplug the charger from the AC outlet first and then disconnect the batteries with charger.
AUTOMATIC CHARGE STAGE
Stage 1 - Diagnosis: Analyse if the battery can accept a charge or not, and then prevent charging from proceeding on the a
defective battery;
Stage 2 - Desulphation: The charger can rescue most drained batteries with voltages up to a Min 1.5±0.5V
Stage 3 - Pre-charge: If the battery voltage is less than 12V, charge it at the smaller current, which will protect the battery better;
Stage 4 - Soft start: Charge the battery to the maximum current gradually and never suddenly.
Stage 5 - CC1/CC2/CC3 (Constant Current): The charger automatically adjusts the current according to the battery status in
constant current, which benefits the battery for a long life;
Stage 6- CV (Constant Voltage): The battery is charged to nearly full, and will top off at 14.6V DC;
Stage 7 - Resting: The charger will cut off with full charged statement, and achieves the high energy efficiency;
Stage 8 - Recondition: When it is fully charged and low to 12.8V within 2min, the charger will judge automatically.
Stage 9 - Restoring: The charger monitors a fully charged battery automatically. If the battery falls below 12.8V DC, the charger
will restart from stage 4 to stage 7.