  • Page 1 INSTRUCTION MANUAL...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 17 Low Battery Alert Indication 17 Auto Shut-Down to Preserve Battery Life Introduction 18 Calibration of Your C555 C555 Parts 20 Protective Rubber Boot for Quick Start: Basic Use for Your C555 Concrete 22 Summary of C555 Features...
  • Page 3: Introduction

    Your model C555 has the built-in capability to capture and record relative humidity and temperature readings to determine ambient or service conditions. The C555 is designed to give an average moisture indication of the area it is scanning. However, using...
  • Page 4: C555 Parts

    AUDIO number. If this is the first time you are BUTTON BUTTON using your new C555, the meter display should revert to Standard Measurement mode for concrete immediately after the revision number is displayed, with the display showing C 0.0 when the meter is held in the air.
  • Page 5: Correct Usage Guidelines For Your C555 Moisture Meter

    (e.g., 34.5%). After 3.5 To make sure that you are getting the seconds, the mode will change to temperature most accurate readings from your C555 and DEG will display, then toggle to the meter, Wagner Meters recommends that ambient temperature (e.g., 75.1F).
  • Page 6: Function Buttons: Detailed

    FUNCTION BUTTONS: meter (opposite side of the display). To take a valid measurement, the DETAILED USAGE INSTRUCTIONS sensor plate must be completely covered with the material you are ON/HOLD Button measuring. If the sensor plate is not completely covered, your moisture reading will be inaccurate.
  • Page 7: Up And Down Buttons

    The available modes are: NOTE: The C555 will shut down automatically after 60 seconds if the meter is left on HOLD Concrete Reading Mode. Press the with no measurement activity. Pressing the...
  • Page 8 to be tested and press down slightly the sensor plate, 0 will be displayed. but firmly, making sure the sensor While in this mode, REL will show in rests flat against the concrete. Take the lower-left corner of the display. several readings close to each other.
  • Page 9: Relative Scale For Moisture

    UP or DOWN ON/HOLD button. arrow key. AUDIO Button Your C555 AUDIO button allows you to set a high moisture content alarm threshold (setting from 0.0 to 6.9) for material measurement applications, and also set the volume for the audible alarm.
  • Page 10 Press the AUDIO button and the display (1) the setting will wrap around to the will show the current moisture content maximum (6.9) and continue to decrease high threshold (e.g., 6.4). The factory default from there. is 2.0. Each press and release of the UP or DOWN buttons will adjust the threshold Next, press the AUDIO setting by 0.1.
  • Page 11: Low Battery Alert Indication

    Low Battery Alert Indication Calibration of Your C555 When the battery is low, BAT appears If you have reason to believe your C555 in the upper right-hand corner of the may be out of calibration, it can be easily display. If ignored for too long, the meter...
  • Page 12: Protective Rubber Boot For Your C555

    The meter will make a beeping sound which indicates it is going through the automatic calibration procedure. If, after recalibrating the C555, there is still a problem with the meter, please When the calibration procedure is contact a Wagner representative for further...
  • Page 13: Summary Of C555 Features

    SUMMARY OF C555 FEATURES • Relative Humidity & Temperature mode • Moisture content measurement range for concrete 0% to 6.9% (the display will show 0 to 6.9) • Digital display resolution of 0.1% (in Standard Measurement mode) • Relative scale for testing non-concrete...
  • Page 14: Specifications

    • +50˚F to +90˚F (+10˚C to +32˚C), Maximum that it be stored in the hard shell carrying relative humidity of 95%, non-condensing case provided with each C555 meter. After Operating Temperature each use, clean the meter case with a soft •...
  • Page 15: Warranty

    (1) makes no guarantee that the meter will stay year from the date of purchase on all C555 in calibration for any specific period of time. moisture meters, subject to the following...
  • Page 16: Glossary Of Terms

    If the meter fails to calibrate properly an officer of Wagner Meters, do not constitute then it should be sent to the factory for a warranties and should not be relied upon by diagnostic checkup. the customer. When instructed to return a meter,...
  • Page 17 Rogue River, OR 97537 Worldwide Toll-Free: 844-746-3764 WWW.WAGNERMETERS.COM ©Wagner Meters 2019 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of the publisher.