Step
3
Slide the intermediate
bearing to the right and
remove the fan rotor
assy.
Remove the 2 fan
4
motor fasteners.
5
Remove the fan motor.
Removal Procedure
Procedure
Procedure to Remove Fan Rotor and Motor
Points
∗ Finally reconnect the fan
motor connector, cover it
with the glass tube and
secure it with the tie-wrap.
7

Hide quick links: