Measuring Systems, X2 - Pilz PSEN enc m2 eCAM Operating Manual

Position monitoring
Table of Contents

Advertisement

Installation / Preparation for commissioning

5.5.2 Measuring systems, X2

PIN
Signal
N.C.
1
2
INK A–
3
INK A+
4
N.C.
5
INK B–
6
INK B+
7
SL_m –
8
SL_m +
9
MA_m –
10
MA_m +
11
SL_s –
12
SL_s +
13
MA_s –
14
MA_s +
Description
Do not connect!
Channel A –, RS422
Channel A +, RS422
Do not connect!
Channel B –, RS422
Channel B +, RS422
Data –, measuring channel 1, differential RS422
Data +, measuring channel 1, differential RS422
Clock –, measuring channel 1, differential RS422
Clock +, measuring channel 1, differential RS422
Data –, measuring channel 2, differential RS422
Data +, measuring channel 2, differential RS422
Clock –, measuring channel 2, differential RS422
Clock +, measuring channel 2, differential RS422