Environmental specifications
Table 2
lists the HBA environmental specifications.
Table 2 HBA environmental specifications
Environment
Operating temperature
Storage temperature
Relative humidity (noncondensing)
Storage humidity (noncondensing)
Physical specifications
Table 3
lists the HBA specifications.
Table 3 HBA specifications
Type
Bus interface
Fibre Channel specifications
Central processing unit (CPU)
Memory
Signal voltage
Data rate
Onboard DMA
Frame Buffers
Ports
Connectors
Form factor
Bracket size
Power consumption
10
HBA features
Minimum
0 °C/32 °F
-20 °C/-4 °F
10%
5%
Specification
64-bit, PCI-X 2.0 266-MHz DDR, compatible with 66/33-MHz PCI
and 133/100/66-MHz PCI-X
Conforms to PCI Local Bus Specification, revision 2.3, PCI Bus
Power Management Interface Specification, revision 1.1, PCI Hot
Plug Specification, revision 1.0
Bus type: fiber optic media
Bus transfer rate: 4Gb/s FC increases aggregate throughput rate
to 800 MB/s in full-duplex mode
Single-chip design that includes a RISC processor, Fibre
Channel protocol manager, PCI-XDMA controller, integrated
serializer/deserializer (SEREDES), and electrical transceivers that
can autonegotiate a data rate of 4 Gb/s
1-MB SRAM, 1-MB flash (SPI), and 2-KB NVRAM (SPI)
3.3 V (mode 1), 3.3 V/1.5 V (mode 2)
4, 2, 1 Gb/s auto-negotiation (4.2480/2.1240/1.0625 Gb/s)
Five-channel DMA controller: two data and one command, one
auto-DMA request, and one auto-DMA response.
Integrated 10-KB frame buffer FIFOs (6-KB receive and
4-KB transmit) for each data channel.
Single or dual 4 Gb/s
Small-form-factor fixed (SFF) multimode optic with LC connector
Low-profile MD2: 16.93 cm × 5.15 cm (6.7 in. × 2.5 in.)
Standard: 1.84 cm × 12.08 cm (0.73 in. × 4.76 in.)
Low-profile: 1.84 cm × 8.01 cm (0.73 in. × 3.15 in.)
~11.0 Watts
Maximum
55 °C/131 °F
70 °C/158 °F
90%
95%