DISPLAY LIGHTS ON INTEGRATED HEATER CONTROL

LED
STATUS
Calling for heat
The ECO (Energy Cut-Out) has
opened.
No power
Tank is at a set temperature ± 2° F.
Tank has cooled below 120° F.
Preceded by "ECO Open" indication.
INDICATION
Servicing should only be performed by a Qualified Service Technician
ACTION
Normal status. No action required.
Check for excessively hot water (203° F or
higher).
Check the resistance of the temperature
probes and continuity of the high limit (ECO).
Check the breaker.
No action required.
Push the manual reset button.
Check the resistance of the temperature
probes and continuity of the high limit (ECO).