7. INSTALLATION

In this section you will find all the information
necessary to install the MEC MIX C - MEC MIX F
series generators from a hydraulic point of view.
7.1 GENERAL INSTALLATION RULES APPLIANCE
The installation must be carried out, according to
the manufacturer's instructions, by professionally
qualified personnel;
For professionally qualified personnel means those
with specific technical competence in the sector of
heating system components.
In any case, by calling the Presale office of A2B
Accorroni E.G. srl (phone +39.071.723991) you can
receive the necessary information.
Incorrect installation can cause damage to people,
animals and things, against which the manufacturer
can not be held responsible.
However, comply with the regulations in force and in
particular:
- to the D.M. of 12 April 1996 containing the rules of
fire prevention for the design, the construction and
operation of thermal plants powered by gaseous
fuels.
- D.P.R. n. 412/93 which regulates the design,
installation, operation and maintenance of thermal
plants.
- D.P.R. n. 551/99 which introduces some
modifications to the D.P.R. n. 412/93.
DISTANCES OF RESPECT MEC MIX C AXIALS
A
SECTION C - HYDRAULIC INSTALLER
A
B
- Legislative Decree 192/05 "Implementation of the
Directive 2002 / 91CE on energy efficiency in
Building "and the subsequent Legislative Decree
311/06 "Corrective and supplementary provisions
to the decree legislative 19 August 2005, n. 192 ".
- To the law n. 46/90 and the related regulation of
implementation (D.P.R. 447/91) on the safety of
thermal plants.
- To the UNI CIG 7129 standard that regulates the
installation of gas-powered appliances natural.
- To the UNI CIG 7131 standard that regulates the
installation of appliances powered by LPG
- To the UNI 11071 standard that regulates the
installation of heat generators a condensation.
- To the law n. 186 of March 1, 1968 concerning the
installation of electrical systems. For the installation
is good to respect the following requirements:
- the distance between the back side of the generator
and the wall must be sufficient to allow it air intake
(minimum 330 mm). The distance minimum from
the side walls is shown in Figure 21.
- The distance from the bottom of the generator
to any object or structure below it cm must be
not less than 50 cm to allow installation and
maintenance of the condensate drain siphon.
- The optimal height recommended from the ground
to the base of the generator is 2.5 - 3.5 m (see
Figure 15 A / B). Heights below 2.5 meters are not
recommended in as the flow of air coming out of
A min 200 cm
B min 250 cm
max. 350 cm
C min 40 cm
D min 50 cm
E min 33 cm
D
27
C
E
OBJECT
OR
STRUCTURE
Fig. 15 A
Fig.15 A