Connections - Electrical - Rheem 812 Series Owner's Manual And Installation Instructions

Continuous flow gas water heater
Table of Contents

Advertisement

All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the
Wiring Rules AS/NZS 3000 and all local codes and regulatory authority requirements.
Warning: Temperature controllers must not be fitted to this water heater (874 series) if it is installed as an
in-series gas booster with a solar water heater system because water at a temperature much higher than the
controller setting can be delivered. If a solar water heater is installed to an existing water heater installation,
then all controllers must be disconnected and removed.
The water heater is supplied with a 1.8 metre lead and plug and requires a weatherproof 240 V AC 50 Hz
general purpose outlet (GPO) to be located within 1.2 metres of the installation. The GPO must be clear of the
flue exhaust, draining water, gas supply pipe and water connections.
The power consumption of the water heater is:
874812, 876812
Model
Natural
Propane
Universal LG Gas
874812, 876812
Model
Natural
Propane
Universal LG Gas
The water heater will only operate on a sine wave at 50 Hz. Devices generating a square wave cannot be used
to supply power to the water heater.
CONNECTIONS – ELECTRICAL
Power consumption (watts) - Burner on, anti-frost device inactive
874816
874T16, 876T16
33
36
-
Power consumption (watts) - Burner on, anti-frost device active
874816
874T16, 876T16
101
106
104
108
-
106
874820, 876820
38
44
40
50
38
47
874820, 876820
112
118
115
63
874826, 876826
874T26, 876T26
54
59
59
874826, 876826
874T26, 876T26
122
127
127