CAPACITY: 400 GALLONS (1514 LITERS)
FLOW RATE: .5 GPM (1.89 LPM)
• OPERATING PSI OF SUPPLY: 30 - 100 PSI
(2.07-6.89 BAR)
• OPERATING TEMPERATURE: 34 - 100 ο F (1.1-
ο
37.8
C)
NOTE: This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below.The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as speci-
fied in NSF/ANSI 42 and 53.
CONTAMINANT
ALACHLOR
ATRAZINE
BENZENE
CARBOFURAN
CARBON TETRACHLORIDE
CHLOROBENZENE
CHLOROPICRIN
2,4-D
DIBROMOCHLOROPROPANE (DBCP)
O-DICHLOROBENZENE
P-DICHLOROBENZENE
1,2-DICHLOROETHANE
1,1-DICHLOROETHYLENE
CIS- 1,2-DICHLOROETHYLENE
TRANS- 1,2-DICHLOROETHYLENE
1,2-DICHLOROPROPANE
CIS-1,3-DICHLOROPROPYLENE
DINOSEB
ENDRIN
ETHYLBENZENE
ETHYLENE DIBROMIDE (EDB)
HALOACENTONITRILES (HAN):
BROMOCHLOROACETONITRILE
DIBROMOACETONITRILE
DICHLOROACETONITRILE
TRICHLOROACETONITRILE
HALOKETONES (HK):
1,1-DICHLORO-2-PROPANONE
1,1,1-TRICHLORO-2-PROPANE
HEPTACHLOR
HEPTACHLOR EPOXIDE
HEXACHLOROBUTADIENE
HEXACHLOROCYCLOPENTADIENE
LINDANE
METHOXYCHLOR
PENTACHLOROPHENOL
SIMAZINE
STYRENE
1,1,2,2-TETRACHLOROETHANE
TETRACHLOROETHYLENE
TOLUENE
TRIBROMOACETIC ACID
2,4,5-TP (SILVEX)
1,2,4-TRICHLOROBENZENE
1,1,1-TRICHLOROETHANE
1,1,2-TRICHLORETHANE
TRICHLOROETHYLENE
TRIHALOMETHANES
XYLENES (TOTAL)
14
PERFORMANCE DATA SHEET - page 1 of 2
RainSoft HYDREFINER II- SC models
DRINKING WATER FILTRATION SYSTEM
MAXIMUM PERMIS-
INFLUENT
SIBLE PRODUCT
CHALLENGE
WATER
CONCENTRA-
CONCENTRATION
TION mg/L
mg/L
0.050
0.001
0.100
0.003
0.081
0.001
0.190
0.001
0.078
0.0018
0.077
0.001
0.015
0.0002
0.110
0.0017
0.052
0.00002
0.080
0.001
0.040
0.001
0.088
0.0048
0.083
0.001
0.170
0.0005
0.086
0.001
0.080
0.001
0.079
0.001
0.170
0.0002
0.053
0.00059
0.088
0.001
0.044
0.00002
0.022
0.0005
0.024
0.0006
0.0096
0.0002
0.015
0.0003
0.0072
0.0001
0.0082
0.0003
0.025
0.00001
0.011
0.0002
0.044
0.001
0.060
0.000002
0.055
0.00001
0.050
0.0001
0.096
0.001
0.120
0.004
0.150
0.0005
0.081
0.001
0.081
0.001
0.078
0.001
0.042
0.001
0.270
0.0016
0.160
0.0005
0.084
0.0046
0.150
0.0005
0.180
0.001
0.300
0.015
0.070
0.001
ACTIVATED CARBON
WATER FILTER SYSTEM
REPLACEMENT FILTERS
DESCRIPTION
PRE-FILTER(5 MICRON SEDIMENT
)
FILTER
POST-FILTER ( HYII CARBON FIL-
TER)
CONTAMINANT REDUCED
USEPA
MCL
(MG/L)
CONTAMINANT
0.002
0.003
LEAD
0.005
MTBE
0.04
MERCURY
0.005
ADDITIONAL CONTAMINANT REDUCED
0.1
--------
CONTAMINANT
0.07
0.0002
0.60
PARTICULATE, CLASS 1 PARTI-
CLES 0.5 TO < 1 ìm
0.075
0.005
ASTHETIC CHLORINE
0.007
VOC
0.07
CYSTS (Cryptosporidium,
0.10
Giardia lamblia, Protozoan)
0.005
ASBESTOS
--------
0.007
THE UNIT SHOULD BE INSTALLED IN AN AREA NOT AFFECTED BY EXTREME
HEAT, COLD OR THE ELEMENTS. THE AREA MUST ALLOW THE SYSTEM TO
0.002
BE SERVICED QUICKLY AND EASILY TO CHANGE THE CARTRIDGE.
0.70
0.00005
THIS SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE
STATE AND LOCAL LAWS AND REGULATIONS.
----------
DO NOT USE WITH WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF
----------
UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR
AFTER THE SYSTEM.
----------
----------
TESTED UNDER STANDARD LABORATORY CONDITIONS, ACTUAL RESULTS MAY
VARY DUE TO LOCAL WATER CONDITIONS.
--------
THIS PERFORMANCE DATA SHEET IS NOT FOR USE IN CALIFORNIA.
--------
0.0004
0.0002
--------
0.05
0.0002
0.04
0.001
0.004
0.10
--------
0.005
1.00
--------
0.05
0.07
0.20
IMPORTANT NOTICE: READ THIS PERFORMANCE DATA
0.005
SHEET AND COMPARE THE CAPABILITIES OF THIS UNIT
0.005
WITH YOUR ACTUAL WATER TREATMENT NEEDS. IT IS
RECOMMENDED THAT BEFORE PURCHASING A WATER
0.08
TREATMENT UNIT YOU HAVE YOUR WATER SUPPLY TEST-
10
ED TO DETERMINE YOUR ACTUAL WATER TREATMENT
NEEDS.
PART NUMBER
51639
51845
MAXIMUM PERMISSI-
INFLUENT CHAL-
BLE PRODUCT
LENGE CONCENTRA-
WATER CONCENTRA-
TION (mg/L)
TION (mg/L)
0.15 +/- 10%
0.0100
%
0.0050
0.015 +/- 20
0.006 +/- 10%
0.0020
I
NFLUENT CHAL-
REDUCTION
LENGE CONCENTRA-
REQUIREMENT
TION (mg/L)
at least 10,000 parti-
>/= 85% Reduction
cles/mL
2.0+/-10%
50% REDUCTION
.
95% REDUCTION
30+/- 30
50,000/L
99.95% Reduction
99% Reduction
10(7) - 10(8) fibers/L
TESTED AND CERTIFIED BY WQA AGAINST
NSF/ANSI STANDARD 42 FOR THE
REDUCTION OF AESTHETIC CHLORINE,
CLASS I NOMINAL PARTICULATE, AND
TASTE AND ODOR.
TESTED AND CERTIFIED BY WQA AGAINST
NSF/ANSI STANDARD 53 FOR
ASBESTOS,CYST, LEAD, MTBE, MERCURY,
AND VOC REDUCTION.
TESTED AND CERTIFIED BY WQA AGAINST
NSF/ANSI STANDARD 372 FOR LOW LEAD
COMPLIANCE.