Troubleshooting Guide - Rain Soft Hydrefiner II Owner's Manual

Premium drinking water system
Table of Contents

Advertisement

Troubleshooting Guide

Symptom
1. Taste/Odor (general)
2. Rotten Egg Odor
3. Odor with Color on
the Filter Cartridge
4. "Milky" Color in
Water or in Ice
Cubes
5. No / Low Pressure at
outlet.
If the troubleshooting guide did not resolve the symptom, please contact your local RainSoft Dealer for service. If
you cannot locate your local RainSoft Dealer, please contact RainSoft Customer Service at 1-800-860-7638 or log
onto www.rainsoft.com for the name and location of your nearest Dealer.
Cause
1. The filter cartridge may be saturated.
1. Typically a sign that H
S (Hydrogen Sulfide)
2
gas, which can occur at any time,is present in
the water.
1. H
S (Hydrogen Sulfide) caused by iron
2
(orange/blackish color) and/or decaying
organisms (slimy; blotchy colors).
1. Small air bubbles are passing through the
system.
2. Air is trapped inside the filter housing.
3. Have your water tested for the concentration
of total dissolved solids (TDS). The higher the
TDS concentration, the cloudier the ice will
tend to be.
1. Water Supply is Turned Off.
2. Water Supply is Blocked.
3. Sediment cartridge is Fouled.
4. Incoming water line is crimped or pinched
off.
Solution
1. Replace the filter cartridge.
1. Treat the water for hydrogen sulfide
reduction. Replace the filter cartridge.
This system has not been tested or approved
for the reduction of hydrogen sulfide.
1. Have your water tested for the presence of
iron and/or sulfur bacteria; if present, seek
professional advice on proper well cleaning/
disinfection/treatment. If no iron/sulfur
bacteria are detected, then treat the water for
hydrogen sulfide reduction using an
appropriate device. This system has not been
tested or approved for the reduction of iron
bacteria, sulfur bacteria, or hydrogen sulfide.
1. Air bubbles do not affect the performance of
the system.
2. Open the faucet and let the water run for 3
to 5 minutes after installation and filter
changes.
3. Reduce the TDS concentration using
deionization, distillation, or reverse osmosis.
This system has not been tested or approved
for the reduction of TDS.
1. Turn on the Water.
2. Clear Blockage. If this does not work,
Blockage could be internal to the Hydrefiner
II or external with the water line. Contact
your Rainsoft Dealer for issues wth the
Hydrefiner II.
3. Replace Sediment Cartridge - Contact your
Rainsoft Dealer for New Filters
4. Check incoming line and verify no crimps in
line. Remove any pinch points.