T40 Installation and Assembly
1. Position cabinet floor on a flat, level serface with the
slotted end facing up
- Ensure the entryway is facing forward (grey plastic
transition piece.)
- Insert one alignment block to the channel in between
each of the locking cams.
2. Raise the first panel (with the evaporator, fans and air
channel) onto the mounting floor with the fans facing
inside.
- Place bottom of the panel into the alignment channel
on the mounting floor for proper placement, using the
alignment block to align panel.
28
NOTE: Do not break alignment block when placing panels
in place.
The first panel will be the left side of the unit you are
facing the door.
NOTE: Ensure all cam locks are in the open position before
placing any panels.
Make sure the skirt on the vertical panels
covers the outside of the mounting floor.
Lock botton locking cams on
the outside of the first panel.
Insert T-Handle wrench
and twist clockwise until a
positive stop is acheived.
The panel will now stand on
its own.
NOTE: Do not lean or push on unsupported
panels.
NOTE: Do not break alignment block when placing panels
in place.
Lock the side locking cams on the outside of the first
panel and the left side and bottom locking cams on the
inside of the back panel. Insert T-handle wrench and twist
until a positive stop is achieved.
- Attach deflector shields either side of
the first panel as shown. The deflector
shields with cover the corners on the first
panel and are attached with provided
screws.
Section 4
3. Attach the back panel to the
mounting floor in the same
manner as the first panel. The
back panel will wrap around
both sides.
NOTE: Ensure all cam locks are in
the open position before placing
any panels.