E RR OR DET EC TION
If you use a wireless remote control,
the lamp on the photo detector unit will output error
codes by way of blinking patterns.
If you use a wired remote control,
error codes will appear on the remote control display.
See the lamp blinking patterns and error codes in the table.
An error display is displayed only during operation.
Troubleshooting with the indoor unit display
OPERATION indicator (green)
TIMER indicator (orange)
ECONOMY indicator (green)
Troubleshooting with the Wired
Remote Control Display (Option)
If an error occurs, the following display will be shown.
("Er" will appear in the set room temperature display.)
Error code
2016.11.09
Error display
Wired
remote
OPERATION
TIMER
ECONOMY
controller
lamp
lamp
lamp
Error code
(green)
(orange)
(green)
Serial communication error
(1)
(1)
Wired remote controller
(1)
(2)
communication error
Check run unfinished
(1)
(5)
Unit number or Refrigerant circuit
address setting error
(2)
(1)
[Simultaneous Multi]
Indoor unit capacity error
(2)
(2)
Combination error
(2)
(3)
• Connection unit number error
(2)
(4)
• Connection unit number error
Master unit, slave unit set-up
(2)
(7)
error [Simultaneous Multi]
Indoor unit PCB model
(3)
(2)
information error
Manual auto switch error
(3)
(5)
Room temp. sensor error
(4)
(1)
Indoor unit Heat Ex. Middle temp.
(4)
(2)
sensor error
Indoor unit fan motor error
(5)
(1)
Drain pump error
(5)
(3)
Damper error
(5)
(7)
Intake grille error
(5)
(8)
Indoor unit error
(5)
(15)
Outdoor unit main PCB model
(6)
(2)
information error or
communication error
Inverter error
(6)
(3)
Active filter error, PFC circuit er-
(6)
(4)
ror
Trip terminal L error
(6)
(5)
8
(6)
Description
(7)
(7)
(7)
(7)
(7)
(7)
(7)
(8)
(indoor slave unit)
[Simultaneous Multi]
(8)
(indoor unit or branch unit)
[Flexible Multi]
(8)
(8)
(9)
(9)
(9)
(9)
(10)
(10)
(10)
(10)
(13)
Display mode
( ) : Number of flashing
Display PCB microcomputers
(10)
communication error
Discharge temp. sensor error
(1)
Compressor temp. sensor error
(2)
Outdoor unit Heat Ex. liquid
(3)
temp. sensor error
Outdoor temp. sensor error
(4)
Suction Gas temp. sensor error
(5)
2-way valve temp. sensor error
(6)
3-way valve temp. sensor error
Heat sink temp. sensor error
(7)
Sub-cool Heat Ex. gas inlet
temp. sensor error
(2)
Sub-cool Heat Ex. gas outlet
temp. sensor error
Liquid pipe temp. sensor error
(3)
Current sensor error
(4)
Discharge pressure sensor
error
(6)
Suction pressure sensor error
High pressure switch error
Trip detection
(4)
Compressor rotor position
(5)
detection error
Outdoor unit fan motor error
(7)
4-way valve error
(9)
Discharge temp. error
(1)
Compressor temp. error
(3)
High pressure error
(4)
Low pressure error
(5)
Branch boxes error
(2)
[Flexible Multi]