Connect Electrical Supply - Bosch HCP50652UC Installation Manual

Hide thumbs Also See for HCP50652UC:
Table of Contents

Advertisement

Available languages

Available languages

10. Tighten the upper and lower screws by hand.
Connecting the air extractor (only for ducted operation)
Note: If an aluminum pipe is used, smooth the connection
area beforehand.
1. Attach exhaust air pipe and seal.
2. Check whether the back-pressure flap works.
Mounting the recirculation model
(only for circulating-air mode)
1. Use 4 screws (4x8 mm) to screw the housing to the
angle bracket.
C
A Screws
B Recirculation module
C Angle bracket
2. Measure the distance (x) between the bottom edge of
the housing for the recirculation module and the
bottom edge of the back-pressure flap.
B
C
D
A Recirculation module
B Clamps
Page 10
A
B
A
x
C Flue duct
D Exhaust air duct
3. Shorten the exhaust air pipe to the length measured.
4. Remove the recirculation module.
5. Push the exhaust air pipe onto the bottom side of the
recirculation module.
6. Position the recirculation module with exhaust air pipe
over the air extraction duct of the extractor hood.
7. Use 4 screws to fasten the recirculation module to the
angle bracket.
8. Secure connections with clamps.

Connect Electrical Supply

WARNING
RISK OF ELECTRIC SHOCK
Before wiring the appliance, interrupt the main electrical
circuit at the electrical control cabinet. A circuit with 120
VAC, 15 or 20 Ampere is required.
Grounding notes: this appliance is equipped with a
distributor box with 3 cables. Use the green-yellow cable
for grounding the appliance. Connect the green-yellow
cable to the grounding cable on the house connection to
prevent electric sthock. Do not under any circumstances
damage or remove the green-yellow cable. Non-adheren-
ce can cause serious injuries or electric shock.
1. Unplug the cable connector located on the top of the
junction box.
2. Remove the cable passage and the junction box cover.
A
A Cable passage
B Cover of the junction box
3. Connect 1/2" (12.7 mm) strain relief to the junction box.
4. Run home power supply cable through strain relief,
into terminal box.
5. Use UL listed wire connectors and connect black wires
(C) together.
6. Use UL listed wire connectors and connect white wires
(D) together.
B