1-4. Other Notice
1. The exhaust system will be very hot, so to protect electrical parts such as the starter, the alternator, fuel system parts, wiring,
etc. around the exhaust system and for the safety of operators, FEA should install heat shields or insulating blankets as
necessary. It is acceptable to wrap the DOC if necessary. However, heat shield must not be welded to the DOC. The
temperature of these surrounding components must be confirmed during the application review and must be within the
prescribed limits shown in the application review form.
2. Confirm that water does not enter the exhaust system from the tail pipe outlet in all operating conditions. If water entry is
possible, install a rain cover or similar device.
1. Exhaust System
Kubota Emission-Related Installation Instructions
Document Number : KEA-STD-03-CRS-DOC-001-