4.3 LED Status

LED status symbols:
Board
LED No.
SPU
CR1 (YLW)
Board
CR2 (YLW)
(03P9253)
CR3 (YLW)
CR4 (YLW)
CR5 (YLW)
CR6 (YLW)
CR7 (YLW)
CR8 (YLW)
RP
CR1 (YLW)
Board
(14P0298)
ARP
CR1 (YLW)
Board,
CR9 (RED)
AC
CR10 (RED)
(18P9002)
CR11 (RED)
CR12 (RED)
CR13 (YLW)
CR14 (YLW)
CR15 (RED)
CR16 (RED)
CR17 (YLW)
CR32 (YLW)
PTU
CR11 (RED)
Board,
AC
CR12 (RED)
(03P9245)
PTU
CR11 (RED)
Board,
DC
CR12 (RED)
(03P9246)


: OFF ;
: Blinking ;
Normal
Check
Status
Item

KEY TX

NAV TX
Blinks every 3 seconds.

RJ7 TX
Blinks when RJ-7 is connected.

INS TX
Not used

KEY RX
Lights momentary when key is
pressed.

NAV RX
Blinks when receiving nav
data.

RJ7 RX
Blinks when RJ-7 is connected.

INS RX
Blinks when receiving nav
data.

CPU CLK Blinks every second.

CPU CLK Blinks at irregular interval

HDG
Lights if heading data is not
alarm
received for more than 10 sec.

BP
Lights if bearing data is not
received for more than 10 sec.
alarm

Video
Lights if video data is not
alarm
received for more than 60 sec.

TRIG
Lights if trigger is not received
alarm
more than 10 sec.


TRIG
Lights if trigger PRR is less
or
freq.
than 1250 Hz (S2).

TRIG
Not used
freq.

Gyro
Lights if gyro data is not
alarm
received for more than 10 sec.

Log alarm Lights if log data is not received
more than 60 sec.

DSP CLK Blinks every 2 seconds


FE echo
Lights when echo data is
or
data
received.

Over-volt. Lights when ship's mains
exceeds the rating.

Over-cur. Lights if over-current is
detected.

Over-volt.

Over-cur.

: ON
Remarks
4-4
Location of LEDs
CR4
CR8
CR7
CR3
CR6
CR2
CR5
CR1
FR2115-SME-25A
FR2115-SME-25B
CR12
CR32
CR11
CR16
CR10
CR15
CR9
CR1
CR17
CR14
CR13
CR12
CR11
Same as above
CR1
FR2115-SME-24A
FR2115-SME-25C

Hide quick links: