MOUNTING THE CONTROL BOX

Use the four screws and if necessary the wall anchors to mount the control box to the
wall. A screwdriver and a drill are needed. You can mount the unit horizontal or
vertical.
PUTTING THE SCALEWATCHER
Insert the 12VDC plug of the adaptor into the power jack at the side of the
SCALEWATCHER™ and connect the adaptor to either 110V or 220 V AC.
The bar graph should start flashing indicating coil connected and correct signal being
generated.
The LED's should behave as follows: two bottom lights constantly ON, lights above
flashing in a continuous up and down motion.

TROUBLESHOOTING

LED'S fail to light up:
Verify coil connections, verify power supply. If the problem persists contact your
supplier
Two bottom LED's flicker instead of cycling up and down:
Unplug the unit, wait a few seconds and plug back on. (This reboots the system).
For any installation questions please contact your supplier.